Three-dimensional motion estimation with image reconstruction for gated cardiac ECT

被引:23
作者
Cao, ZX [1 ]
Gilland, DR
Mari, BA
Jaszczak, RJ
机构
[1] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Nucl & Radiol Engn Dept, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Math, Gainesville, FL 32611 USA
[4] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[5] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
关键词
cardiac imaging; image reconstruction; positron emission tomography (PET); single photon emission computed tomography; (SPECT);
D O I
10.1109/TNS.2003.812444
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The primary goal of this work was to develop and evaluate a new method for simultaneous three-dimensional motion estimation and image reconstruction for gated cardiac emission computed tomography (ECT). The method employs a two-step iterative procedure for obtaining the motion and reconstructed image estimates. The method was evaluated using both simulated and physical phantoms designed to mimic myocardial perfusion imaging in ECT. In both the simulated and physical phantom studies, the images reconstructed by the simultaneous method showed improved noise characteristics relative to a standard iterative algorithm. The percent error of the motion estimate ranged from 16% to 59% for the simulated phantom study, and 45% to 65% for the physical phantom study, depending on the position within the myocardium.
引用
收藏
页码:384 / 388
页数:5
相关论文
共 12 条
[1]   Three-dimensional reconstructions from low-count SPECT data using deformable models [J].
Cunningham, GS ;
Hanson, KM ;
Battle, XL .
OPTICS EXPRESS, 1998, 2 (06) :227-236
[2]   Simultaneous reconstruction and motion estimation for gated cardiac ECT [J].
Gilland, DR ;
Mair, BA ;
Bowsher, JE ;
Jaszczak, RJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2344-2349
[3]  
GREEN PJ, 1990, J ROY STAT SOC B MET, V52, P443
[4]   Non-rigid summing of gated PET via optical flow [J].
Klein, GJ ;
Reutter, BW ;
Huesman, RH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) :1509-1512
[5]  
LAADING JK, 1999, LECT NOTES COMPUTER, V1613
[6]   Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT [J].
Lalush, DS ;
Tsui, BMW .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :875-886
[7]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[8]  
MAIR BA, 2002, UNPUB IEEE T MED IMA
[9]   Application of the Karhunen-Loeve transform to 4D reconstruction of cardiac gated SPECT images [J].
Narayanan, MV ;
King, MA ;
Soares, EJ ;
Byrne, CL ;
Pretorius, PH ;
Wernick, MN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :1001-1008
[10]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558