Study of the mechanism of enantioseparation.: IV.: Study of enantioseparation of some derivatives of phenylcarbamic acid using π-complex stationary phase in HPLC

被引:15
作者
Dungelová, J
Lehotay, J [1 ]
Cizmarik, J
Armstrong, DW
机构
[1] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Dept Analyt Chem, Bratislava, Slovakia
[2] Comenius Univ, Fac Pharm, Dept Pharmaceut Chem, Bratislava, Slovakia
[3] Iowa State Univ, Dept Chem, Ames, IA USA
关键词
HPLC; enantiomeric separation; (R; R) and (SS) Whelk-O 1 chiral stationary phases; alkoxysubstituted esters of phenylcarbamic acid; study of mechanism;
D O I
10.1081/JLC-120023250
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Whelk-O 1 chiral stationary phase (CSP) is an useful column for the high performance liquid chromatographic (HPLC) resolution of enantiomers of 2-methoxy-1-[(4-methylpiperazino)methyl]ethyl esters of N-(2-,3-, and 4-alkoxyphenyl)carbamic acid (group of the local anaesthetic drugs) in the organic mode and the reversed mode. According to the results of enantiomeric separations in different mobile phases [containing organic modifiers (methanol, acetonitrile, water), with different additives of acetic acid and trimethylamine], it can be postulated that the piperazino part of the phenylcarbamic acid compound is essential because the separation of piperidino, pyrrolidino, and perhydroazepino esters of alkoxy phenylcarbamic acid were not observed. Also the influence of the environment near the analyte's stereogenic is important for enantioseparation. A comparison of the enantiomeric elution order and the configuration of the chiral selector shows that R-(-) enantiomers are more retained on the (R,R) Whelk-O 1 column and S-(+) enantiomers are more retained on the (S,S) Whelk-O 1 column.
引用
收藏
页码:2331 / 2350
页数:20
相关论文
共 20 条
[1]  
CIZMARIK J, 1997, PHARMAZIE, V52, P5
[2]  
DUNGELOVA J, 2002, J LIQ CHROMATOGR R T, V25, P313
[3]  
FREITAG W, 1969, J CHROMATOGR, V41, P473
[4]   OPTIMIZATION OF THE SEPARATION OF ENANTIOMERS OF BASIC DRUGS - RETENTION MECHANISMS AND DYNAMIC MODIFICATION OF THE CHIRAL BONDING PROPERTIES ON AN ALPHA(1)-ACID GLYCOPROTEIN COLUMN [J].
HERMANSSON, J ;
GRAHN, A .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) :57-69
[5]   Liquid chromatographic resolution of 2-hydroxycarboxylic acids a new chiral stationary phase derived from (S)-leucine [J].
Hyun, MH ;
Kang, MH ;
Han, SC .
JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (01) :31-39
[6]  
Hyun MH, 1998, HRC-J HIGH RES CHROM, V21, P69
[7]  
HYUN MH, 1996, J CHROMATOGR A, V732, P69
[8]  
Krstulovic A.M., 1989, Chiral separations by HPLC
[9]   Modification of the chiral bonding properties of teicoplanin chiral stationary phase by organic additives.: HPLC separation of enantiomers of alkoxysubstituted esters of phenylcarbamic acid [J].
Lehotay, J ;
Hrobonová, K ;
Cizmárik, J ;
Renèová, M ;
Armstrong, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (05) :609-624
[10]   High-performance liquid chromatographic separation of the enantiomers of N-aryloxazolinones, N-aryl thiazolinones and their sulfur derivatives on a synthetic chiral stationary phase [J].
Pirkle, WH ;
Koscho, ME ;
Wu, ZP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 726 (1-2) :91-97