Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection

被引:91
作者
de Jong, HWAM [1 ]
Slijpen, ETP [1 ]
Beekman, FJ [1 ]
机构
[1] Univ Utrecht Hosp, Dept Nucl Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
D O I
10.1109/23.910833
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monte Carlo (MC) simulation is an established tool to calculate photon transport through tissue in Emission Computed Tomography (ECT). Since the first appearance of MC a large variety of variance reduction techniques (VRT) have been introduced to speed up these notoriously slow simulations. One example of a very effective and established VRT is known as forced detection (FD). In standard FD the path from the photon's scatter position to the camera is chosen stochastically from the appropriate probability density function (PDF), modeling the distance-dependent detector response. In order to speed up MC we propose a convolution-based FD (CFD) which involves replacing the sampling of the PDF by a convolution with a kernel which depends on the position of the scatter event. We validated CFD for parallel-hole Single Photon Emission Computed Tomography (SPECT) using a digital thorax phantom. Comparison of projections estimated with CFD and standard FD shows that both estimates converge to practically identical projections (maximum bias 0.9% of peak projection value), despite the slightly different photon paths used in CFD and standard FD. Projections generated with CFD converge, however, to a noise-free projection up to one or two orders of magnitude faster, which is extremely useful in many applications such as model-based image reconstruction.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 28 条
[1]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[2]  
BECK JW, 1982, IEEE T NUCL SCI, V29, P506, DOI 10.1109/TNS.1982.4335896
[3]   FAST SPECT SIMULATION INCLUDING OBJECT SHAPE DEPENDENT SCATTER [J].
BEEKMAN, FJ ;
VIERGEVER, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) :271-282
[4]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[5]   Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation [J].
Beekman, FJ ;
de Jong, HWAM ;
Slijpen, ETP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) :N183-N192
[6]   Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation [J].
Beekman, FJ ;
Kamphuis, C ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) :491-499
[7]   The influence of backscatter material on 99mTc and 201Tl line source responses [J].
de Jong, HWAM ;
Beekman, FJ ;
Ljungberg, M ;
van Rijk, PP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :665-679
[8]  
DEJONG HWA, 1999, UTRECHT MONTE CARLO
[9]  
FLOYD CE, 1986, J NUCL MED, V27, P1577
[10]  
Frey E. C., 1996, 1996 IEEE Nuclear Science Symposium Conference Record (Cat. No.96CH35974), P1082, DOI 10.1109/NSSMIC.1996.591559