Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device

被引:36
作者
Al-Karkhi, Isam [1 ]
Al-Rubaiy, Raad [1 ]
Rosenqvist, Ulf [1 ]
Falk, Magnus [1 ]
Nystrom, Fredrik H. [1 ]
机构
[1] Linkoping Univ, Fac Hlth Sci, Dept Med & Hlth Sci, SE-58185 Linkoping, Sweden
关键词
home blood pressure; hypertension; office blood pressure; oscillometric; smoking; HYPERTENSION; VALIDATION;
D O I
10.1097/MBP.0000000000000088
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective We aimed to compare blood pressure (BP) levels recorded using the semiautomatic oscillometric Omron i-C10 BP device in patients with or without hypertension in three different settings: (a) when used by a doctor or a nurse at the office (OBP); (b) when used for self-measurement by the patient at the office (SMOBP); and (c) when used for 7 consecutive days at home (HBP). Materials and methods A total of 247 individuals were invited to participate, but 78 of these individuals declined and a further seven were excluded, leaving a final cohort of 162 participants. Results The mean OBP was higher than HBP (difference 8.1 +/- 14/ 3.1 +/- 8.8 mmHg, P < 0.0001) and so was SMOBP compared with HBP (difference 7.0 +/- 13/ 4.2 +/- 7.3 mmHg, P < 0.0001). Sixteen participants (9.9%) had at least 10 mmHg higher systolic SMOBP than OBP and 28 (17%) participants had at least 10 mmHg lower systolic SMOBP than OBP. Participants who were current smokers had a larger mean difference between systolic OBP and SMOBP than nonsmokers (OBP-SMOBP in smokers: 6.6 +/- 9.4 mmHg, OBP-SMOBP in nonsmokers: 0.5 +/- 9.2 mmHg, P = 0.011 between groups). Conclusion Self-measurement of BP in the office does not preclude an increase in BP when levels in the individual patients are compared with HBP using the same equipment. Thus, SMOBP with a semiautomatic device does not lead to a reduction in the white-coat effect in the same manner as fully automatic devices. Copyright (C) 2015 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 19 条
[1]   Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index [J].
Andreadis, Emmanuel A. ;
Agaliotis, Gerasimos D. ;
Angelopoulos, Epameinondas T. ;
Tsakanikas, Athanasios P. ;
Chaveles, Loannis A. ;
Mousoulis, George P. .
AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) :661-666
[2]   Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol [J].
Coleman, Andrew ;
Steel, Stephen ;
Freeman, Paul ;
de Greeff, Annemarie ;
Shennan, Andrew .
BLOOD PRESSURE MONITORING, 2008, 13 (01) :49-54
[3]   Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension [J].
El Feghali, Ramzi N. ;
Topouchian, Jirar A. ;
Pannier, Bruno M. ;
El Assaad, Hiba A. ;
Asmar, Roland G. .
BLOOD PRESSURE MONITORING, 2007, 12 (03) :173-178
[4]  
Feil Philip H, 2002, J Dent Educ, V66, P1129
[5]   Role of Ambulatory Blood Pressure Monitoring in Hypertension and Diabetes [J].
Flynn, Colleen ;
Bakris, George L. .
CURRENT HYPERTENSION REPORTS, 2013, 15 (03) :137-142
[6]   Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study [J].
Head, Geoffrey A. ;
Mihailidou, Anastasia S. ;
Duggan, Karen A. ;
Beilin, Lawrence J. ;
Berry, Narelle ;
Brown, Mark A. ;
Bune, Alex J. ;
Cowley, Diane ;
Chalmers, John P. ;
Howe, Peter R. C. ;
Hodgson, Jonathan ;
Ludbrook, John ;
Mangoni, Arduino A. ;
McGrath, Barry P. ;
Nelson, Mark R. ;
Sharman, James E. ;
Stowasser, Michael .
BMJ-BRITISH MEDICAL JOURNAL, 2010, 340 :849
[7]   Acute and chronic effects of cigarette smoking on arterial stiffness [J].
Kim, JW ;
Park, CG ;
Hong, SJ ;
Park, SM ;
Rha, SW ;
Seo, HS ;
Oh, DJ ;
Rho, YM .
BLOOD PRESSURE, 2005, 14 (02) :80-85
[8]  
Lim PO, 1996, LANCET, V348, P1445, DOI 10.1016/S0140-6736(04)70085-9
[9]   2013 ESH/ESC Guidelines for themanagement of arterial hypertension The Task Force for the management ofarterial hypertension of the European Society ofHypertension (ESH) and of the European Society of Cardiology (ESC) [J].
Mancia, Giuseppe ;
Fagard, Robert ;
Narkiewicz, Krzysztof ;
Redon, Josep ;
Zanchetti, Alberto ;
Boehm, Michael ;
Christiaens, Thierry ;
Cifkova, Renata ;
De Backer, Guy ;
Dominiczak, Anna ;
Galderisi, Maurizio ;
Grobbee, Diederick E. ;
Jaarsma, Tiny ;
Kirchhof, Paulus ;
Kjeldsen, Sverre E. ;
Laurent, Stephane ;
Manolis, Athanasios J. ;
Nilsson, Peter M. ;
Ruilope, Luis Miguel ;
Schmieder, Roland E. ;
Sirnes, Per Anton ;
Sleight, Peter ;
Viigimaa, Margus ;
Waeber, Bernard ;
Zannad, Faiez ;
Redon, Josep ;
Dominiczak, Anna ;
Narkiewicz, Krzysztof ;
Nilsson, Peter M. ;
Burnier, Michel ;
Viigimaa, Margus ;
Ambrosioni, Ettore ;
Caufield, Mark ;
Coca, Antonio ;
Olsen, Michael Hecht ;
Schmieder, Roland E. ;
Tsioufis, Costas ;
van de Borne, Philippe ;
Zamorano, Jose Luis ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hector ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Fagard, David Hasdai ;
Hoes, Arno W. .
JOURNAL OF HYPERTENSION, 2013, 31 (07) :1281-1357
[10]  
Myers MG, 2014, CAN FAM PHYSICIAN, V60, P127