A myosignal-based powered exoskeleton system

被引:309
作者
Rosen, J [1 ]
Brand, M
Fuchs, MB
Arcan, M
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
[2] Tel Aviv Univ, Fac Engn, Dept Solid Mech Mat & Syst, IL-69978 Tel Aviv, Israel
[3] Tel Aviv Univ, Fac Engn, Dept Biomed Engn, IL-69978 Tel Aviv, Israel
来源
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS | 2001年 / 31卷 / 03期
关键词
arm; electromyography; EMG; exoskeleton; muscle; myosignals; orthotics; upper limb;
D O I
10.1109/3468.925661
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Integrating humans and robotic machines into one system offers multiple opportunities for creating assistive technologies that can be used in biomedical, industrial, and aerospace applications, The scope of the present research is to study the integration of a human arm with a powered exoskeleton (orthotic device) and its experimental implementation in an elbow joint, naturally controlled by the human. The Human-Machine interface was set at the neuromuscular level, by using the neuromuscular signal (EMG) as the primary command signal for the exoskeleton system. The EMG signal along with the joint kinematics were fed into a myoprocessor (Hill-based muscle model) which in turn predicted the muscle moments on the elbow joint. The moment-based control system integrated myoprocessor moment prediction with feedback moments measured at the human arm/exoskeleton and external load/exoskeleton interfaces. The exoskeleton structure under study was a two-link, two-joint mechanism, corresponding to the arm limbs and joints, which was mechanically linked (worn) by the human operator. In the present setup the shoulder joint was kept fixed at given positions and the actuator was mounted on the exoskeleton elbow joint, The operator manipulated an external weight, located at the exoskeleton tip, while feeling a scaled-down version of the load. The remaining external load on the joint was carried by the exoskeleton actuator. Four indices of performance were used to define the quality of the human/machine integration and to evaluate the operational envelope of the system, Experimental tests have shown that synthesizing the processed EMG signals as command signals with the external-load/human-arm moment feedback, significantly improved the mechanical gain of the system, while maintaining natural human control of the system, relative to other control algorithms that used only position or contact forces. The results indicated the feasibility of an EMG-based power exoskeleton system as an integrated human-machine system using high- level neurological signals.
引用
收藏
页码:210 / 222
页数:13
相关论文
共 53 条
[1]   FUNCTIONAL ASSESSMENT OF CONTROL-SYSTEMS FOR CYBERNETIC ELBOW PROSTHESES .2. APPLICATION OF THE TECHNIQUE [J].
ABULHAJ, CJ ;
HOGAN, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (11) :1037-1047
[2]  
Basmajian J. V., 1985, MUSCLE ALIVE
[3]  
BERGAMASCO M, 1994, IEEE INT CONF ROBOT, P1449, DOI 10.1109/ROBOT.1994.351286
[4]  
Blumenstein, 1980, ELECTRODE PLACEMENT
[5]  
BONIVENTO C, 1998, P IEEE INT C CONTR A, V1, P61
[6]  
Brooks F. P. Jr., 1990, Computer Graphics, V24, P177, DOI 10.1145/97880.97899
[7]  
BROWN P, 1993, PROCEEDINGS : IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-3, P642, DOI 10.1109/ROBOT.1993.292051
[8]  
Burdea G., 1996, FORCE TOUCH FEEDBACK
[9]  
CALDWELL DG, 1995, IROS '95 - 1995 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS: HUMAN ROBOT INTERACTION AND COOPERATIVE ROBOTS, PROCEEDINGS, VOL 2, P567, DOI 10.1109/IROS.1995.526273
[10]   SINGLE-SITE ELECTROMYOGRAPH AMPLITUDE ESTIMATION [J].
CLANCY, EA ;
HOGAN, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) :159-167