Transient elastography: A new noninvasive method for assessment of hepatic fibrosis

被引:2113
作者
Sandrin, L
Fourquet, B
Hasquenoph, JM
Yon, S
Fournier, C
Mal, F
Christidis, C
Ziol, M
Poulet, B
Kazemi, F
Beaugrand, M
Palau, R
机构
[1] Echosens, Paris, France
[2] Hop Jean Verdier, Bondy, France
[3] Inst Mutualiste Montsouris, Paris, France
关键词
one-dimensional transient elastography; hepatic fibrosis; chronic hepatitis C; liver stiffness; quantitative palpation; shear wave; shear elasticity probe;
D O I
10.1016/j.ultrasmedbio.2003.07.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Chronic hepatitis is accompanied by progressive deposit of hepatic fibrosis, which may lead to cirrhosis. Evaluation of liver fibrosis is, thus, of great clinical interest and, up to now, has been assessed with liver biopsy. This work aims to evaluate a new noninvasive device to quantify liver fibrosis: the shear elasticity probe or fibroscan(R). This device is based on one-dimensional (1-D) transient elastography, a technique that uses both ultrasound (US) (5 MHz) and low-frequency (50 Hz) elastic waves, whose propagation velocity is directly related to elasticity. The intra- and interoperator reproducibility of the technique, as well as its ability to quantify liver fibrosis, were evaluated in 106 patients with chronic hepatitis C. Liver elasticity measurements were reproducible (standardized coefficient of variation: 3%), operator-independent and well correlated (partial correlation coefficient = 0.71,p < < 0.0001) to fibrosis grade (METAVIR). The areas under the receiver operating characteristic (ROC) curves were 0.88 and 0.99 for the diagnosis of patients with significant fibrosis (greater than or equal to F2) and with cirrhosis ( = F4), respectively. The Fibroscan(R) is a noninvasive, painless, rapid and objective method to quantify liver fibrosis. (E-mail: laurent.sandrin@echosens.com) (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1705 / 1713
页数:9
相关论文
共 38 条
  • [1] SAMPLING VARIABILITY ON PERCUTANEOUS LIVER-BIOPSY
    ABDI, W
    MILLAN, JC
    MEZEY, E
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1979, 139 (06) : 667 - 669
  • [2] An algorithm for the grading of activity in chronic hepatitis C
    Bedossa, P
    Poynard, T
    [J]. HEPATOLOGY, 1996, 24 (02) : 289 - 293
  • [3] BERCOFF J, 2003, 28 2NT S ULTR IM TIS
  • [4] Current concepts: Liver biopsy.
    Bravo, AA
    Sheth, SG
    Chopra, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) : 495 - 500
  • [5] Practices of liver biopsy in France: Results of a prospective nationwide survey
    Cadranel, JF
    Rufat, P
    Degos, F
    [J]. HEPATOLOGY, 2000, 32 (03) : 477 - 481
  • [6] A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
    Catheline, S
    Wu, F
    Fink, M
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (05) : 2941 - 2950
  • [7] Diffraction field of a low frequency vibrator in soft tissues using transient elastography
    Catheline, S
    Thomas, JL
    Wu, F
    Fink, MA
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (04) : 1013 - 1019
  • [8] ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO
    CESPEDES, I
    OPHIR, J
    PONNEKANTI, H
    MAKLAD, N
    [J]. ULTRASONIC IMAGING, 1993, 15 (02) : 73 - 88
  • [9] Young's modulus measurements of soft tissues with application to elasticity imaging
    Chen, EJ
    Novakofski, J
    Jenkins, WK
    OBrien, WD
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (01) : 191 - 194
  • [10] Liver fibrosis - from bench to bedside
    Friedman, SL
    [J]. JOURNAL OF HEPATOLOGY, 2003, 38 : S38 - S53