Evaluation of a novel mononuclear cell isolation procedure for serological HLA typing

被引:38
作者
Schlenke, P
Kluter, H
Muller-Steinhardt, M
Hammers, HJ
Borchert, K
Bein, G
机构
[1] Univ Lubeck, Inst Immunol & Transfus Med, Sch Med, D-23538 Luebeck, Germany
[2] Univ Giessen, Inst Clin Immunol & Transfus Med, D-35392 Giessen, Germany
关键词
D O I
10.1128/CDLI.5.6.808-813.1998
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Despite recent advances in DNA-based genotyping, the microcytotoxicity test is still broadly used for the determination of human leukocyte class I antigens in patients as well as organ donors and also for the detection of HLA antibodies, Excellent purity and viability of peripheral blood mononuclear cells (PBMC) are essential fur reliable HLA typing results. Background staining and cell loss can contribute to impaired typing results or even cause misinterpretations. A novel isolation procedure using cell preparation tubes (CPT) with prefilled Ficoll was compared with the standard Ficoll gradient. We determined the recovery, purity, and viability of the PBMC after several periods of storage. Finally, the isolated cells were used for HLA class I typing, and background reactivities were scored. By using the CPT method, the recovery of PBMC was significantly higher than recovery with the standard technique (P less than or equal to 0.001). Contamination by granulocytes increased considerably during the storage time for the standard protocol, whereas purity remained stable when CPT were used (P less than or equal to 0.001), With both methods, lymphocyte viability declined markedly over time. We found significantly more dead cells by using the CPT methods. Due to high background scores, HLA typing was impossible after 48 h, The isolation of PBMC by the CPT method resulted in a higher yield and improved purity compared to those obtained with the standard gradient technique. The decreasing viability after 48 h limits the use of both methods for HLA typing and HLA antibody screening.
引用
收藏
页码:808 / 813
页数:6
相关论文
共 22 条
  • [1] LYMPHOCYTE SUBSET ANALYSIS BY FLOW-CYTOMETRY - COMPARISON OF 3 DIFFERENT STAINING TECHNIQUES AND EFFECTS OF BLOOD-STORAGE
    ASHMORE, LM
    SHOPP, GM
    EDWARDS, BS
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 118 (02) : 209 - 215
  • [2] RAPID HLA-DRB1 GENOTYPING BY NESTED PCR-AMPLIFICATION
    BEIN, G
    GLASER, R
    KIRCHNER, H
    [J]. TISSUE ANTIGENS, 1992, 39 (02): : 68 - 73
  • [3] COMPLETE SUBTYPING OF THE HLA-A LOCUS BY SEQUENCE-SPECIFIC AMPLIFICATION FOLLOWED BY DIRECT SEQUENCING OR SINGLE-STRAND CONFORMATION POLYMORPHISM ANALYSIS
    BLASCZYK, R
    HAHN, U
    WEHLING, J
    HUHN, D
    SALAMA, A
    [J]. TISSUE ANTIGENS, 1995, 46 (02): : 86 - 95
  • [4] BOYUM A, 1974, TISSUE ANTIGENS, V4, P269
  • [5] BOYUM A, 1968, SCAND J CLIN LAB INV, VS 21, P77
  • [6] SELECTIVE LOSS OF LYMPHOCYTES-OKT8 ON DENSITY GRADIENT CENTRIFUGATION SEPARATION OF BLOOD MONONUCLEAR-CELLS
    DEPAOLI, P
    VILLALTA, D
    BATTISTIN, S
    GASPAROLLO, A
    SANTINI, G
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 61 (02) : 259 - 260
  • [7] GRANULOCYTES IN GRADIENT SEPARATIONS OF STORED-BLOOD
    DZIK, WH
    [J]. TRANSFUSION, 1983, 23 (06) : 538 - 539
  • [8] MONONUCLEAR CELL-SURFACE ANTIGENS DURING STORAGE OF BANKED BLOOD
    DZIK, WH
    NECKERS, L
    [J]. TRANSPLANTATION, 1984, 38 (01) : 67 - 71
  • [9] A RAPID TECHNIQUE FOR LYMPHOCYTE PREPARATION PRIOR TO 2-COLOR IMMUNOFLUORESCENCE ANALYSIS OF LYMPHOCYTE SUBSETS USING FLOW-CYTOMETRY - COMPARISON WITH DENSITY GRADIENT SEPARATION
    MANSOUR, I
    BOURIN, P
    ROUGER, P
    DOINEL, C
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 127 (01) : 61 - 70
  • [10] MULLIS KB, 1987, METHOD ENZYMOL, V155, P335