Multiplex PCR using real time DNA amplification for the rapid detection and quantitation of HTLV I or II

被引:17
作者
Estes, MC [1 ]
Sevall, JS [1 ]
机构
[1] Specialty Labs Inc, Santa Monica, CA 90404 USA
关键词
real-time DNA amplification; HTLV I/II; biplex polymerase chain reaction;
D O I
10.1016/S0890-8508(03)00002-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multiplex 'real-time' polymerase chain reaction (PCR) has been established as a general technique for the quantitation of proviral human T-lymphotrophic virus types 1 and 2 (HTLV-I/II). The technology utilizes fluorescence to measure amplification products from the tax gene of Human T-cell lymphotropic virus type 1 or the 5' long terminal repeat of Human T-cell lymphotropic virus type 2. The quantitative amplification of the standard was linear across four orders of magnitude with nearly identical amplification efficiencies for monoplex or the biplex format from 1.4 copes/assay (60 copies proviral DNA/0.5 micrograms human DNA) to 6000 copies/assay (240,000 proviral copies/0.5 micrograms human DNA). The human beta-globin gene was used to normalize for human DNA input to determine the proviral DNA load. Three hundred fifty-six specimens received by Specialty Laboratories for HTLV I/II detection provided identical results in the detection of HTLV I/II proviral DNA. No additional positive specimens were identified with the biplex assay format. The coefficient of variation for the proviral DNA load was less than 30% for HTLV I or II quantitation (n = 5). For spiked specimens, two groups of five separate 0.25 ml blood specimens (20 total) were spiked, respectively, with 0, 9.6, 48, 240 and 1200 copies of HTLV I or HTLV II DNA standards. The specimens were amplified with the HTLV I/II multiplex format. Twenty of twenty expected negative HTLV I or HTLV II specimens were negative (100% specificity) and 14/16 specimens spiked with 48 copies or more HTLV I were detected (87.5% sensitivity). Thirteen of sixteen HTLV II spiked specimens (>48 copies of HTLV II standard per 10 assays) were detected (81.2%). The real-time detection provides accurate and reliable results in a single amplification for both HTLV (I or II) targets with a more rapid turnaround time and a decrease in material required for results. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 29 条
[1]   Viral genome quantification as a tool for improving patient management: the example of HIV, HBV, HCV and CMV [J].
Berger, A ;
Preiser, W .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2002, 49 (05) :713-721
[2]   Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2000, 25 (02) :169-193
[3]   SINGLE-STEP METHOD OF RNA ISOLATION BY ACID GUANIDINIUM THIOCYANATE PHENOL CHLOROFORM EXTRACTION [J].
CHOMCZYNSKI, P ;
SACCHI, N .
ANALYTICAL BIOCHEMISTRY, 1987, 162 (01) :156-159
[4]   Absence of human T-lymphotropic virus type I tax sequences in a population of normal blood donors in the Baltimore, MD/Washington, DC, area:: results from a multicenter study [J].
Cowan, EP ;
Nemo, GJ ;
Williams, AE ;
Alexander, RK ;
Vallejo, A ;
Hewlett, IK ;
Lal, RB ;
Dezzutti, CS ;
Gallahan, D ;
George, K ;
Pancake, BA ;
Zucker-Franklin, D ;
McCurdy, PR ;
Tabor, E .
TRANSFUSION, 1999, 39 (08) :904-909
[5]   Quantitation of HTLV-I proviral load by a TaqMan real-time PCR assay [J].
Dehée, A ;
Césaire, R ;
Désiré, N ;
Lézin, A ;
Bourdonné, O ;
Béra, O ;
Plumelle, Y ;
Smadja, D ;
Nicolas, JC .
JOURNAL OF VIROLOGICAL METHODS, 2002, 102 (1-2) :37-51
[6]  
Etoh K, 1999, INT J CANCER, V81, P859, DOI 10.1002/(SICI)1097-0215(19990611)81:6<859::AID-IJC4>3.0.CO
[7]  
2-K
[8]   HTLV-I provirus in seronegative Chilean patients with tropical spastic paraparesis [J].
Galeno, H ;
Ramirez, E ;
Cartier, L .
LANCET, 1996, 348 (9035) :1170-1170
[9]  
GESSAIN A, 1985, LANCET, V2, P407
[10]  
GESSIAN A, 1990, BLOOD, V15, P428