Complement and biocompatibility

被引:36
作者
Mollnes, TE [1 ]
机构
[1] Nordland Cent Hosp, Dept Immunol & Transfus Med, N-8017 Bodo, Norway
关键词
D O I
10.1111/j.1423-0410.1998.tb05435.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Blood contact with foreign surfaces induces a certain degree of activation of the defence systems including complement. Recent data using complement specific inhibitors have shown that complement is not only associated with, but in fact contributes to the whole body inflammatory reaction seen as a complication of cardiopulmonary bypass (artificial surfaces) and is responsible for the hyperacute rejection of xenografts (foreign endothelium). Complement activation products, particularly the terminal SC5b-9 complex (TCC), is a sensitive indicator of bioincompatibility. Modifications of the artificial surfaces by coating with heparin improves both coagulation and complement compatibility. The use of specific complement inhibitors in general improves biocompatibility both of artificial materials and foreign endothelium.
引用
收藏
页码:303 / 307
页数:5
相关论文
共 44 条
[1]   SEPARATION OF SELF FROM NON-SELF IN THE COMPLEMENT-SYSTEM [J].
ATKINSON, JP ;
FARRIES, T .
IMMUNOLOGY TODAY, 1987, 8 (7-8) :212-215
[2]   COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - EVIDENCE FOR GENERATION OF C3A AND C5A ANAPHYLATOXINS [J].
CHENOWETH, DE ;
COOPER, SW ;
HUGLI, TE ;
STEWART, RW ;
BLACKSTONE, EH ;
KIRKLIN, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (09) :497-503
[3]   FLUID PHASE GENERATION OF TERMINAL COMPLEMENT COMPLEX AS A NOVEL INDEX OF BIOINCOMPATIBILITY [J].
DEPPISCH, R ;
SCHMITT, V ;
BOMMER, J ;
HANSCH, GM ;
RITZ, E ;
RAUTERBERG, EW .
KIDNEY INTERNATIONAL, 1990, 37 (02) :696-706
[4]   GENERATION OF IC3 AT THE INTERFACE BETWEEN BLOOD AND GAS [J].
EKDAHL, KN ;
NILSSON, B ;
PEKNA, M ;
NILSSON, UR .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1992, 35 (01) :85-91
[5]  
Fiane AE, 1995, TRANSPLANT P, V27, P3560
[6]   Effects of inhibition of complement activation using recombinant soluble complement receptor 1 on neutrophil CD11B/CD18 and L-selectin expression and release of interleukin-8 and elastase in simulated cardiopulmonary bypass [J].
Finn, A ;
Morgan, BP ;
Rebuck, N ;
Klein, N ;
Rogers, CA ;
Hibbs, M ;
Elliott, M ;
Shore, DF ;
Evans, TW ;
Strobel, S ;
Moat, N .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (02) :451-459
[7]  
FOSSE E, 1987, J THORAC CARDIOV SUR, V93, P860
[8]   Duraflo II coating of cardiopulmonary bypass circuits reduces complement activation, but does not affect the release of granulocyte enzymes in fully heparinized patients: A European multicentre study [J].
Fosse, E ;
Thelin, S ;
Svennevig, JL ;
Jansen, P ;
Mollnes, TE ;
Hack, E ;
Venge, P ;
Moen, O ;
Brockmeier, V ;
Dregelid, E ;
Halden, E ;
Hagman, L ;
Videm, V ;
Pedersen, T ;
Mohr, B .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (02) :320-327
[9]   COMPLEMENT ACTIVATION IN EXTRACORPOREAL-CIRCULATION - PHYSIOLOGICAL AND PATHOLOGICAL IMPLICATIONS [J].
GARDINALI, M ;
CIRCARDI, M ;
AGOSTONI, A ;
HUGLI, TE .
PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1986, 5 (3-5) :352-370
[10]  
Garred P, 1997, ARTIF ORGANS, V21, P293