A new technique for direct measurement of the shear force necessary to detach a cell from a material

被引:80
作者
Yamamoto, A
Mishima, S
Maruyama, N
Sumita, M
机构
[1] Natl Res Inst Met Sci & Technol Agcy, Ibaraki, Osaka 3050047, Japan
[2] Olympus Opt Co, Tokyo 1920047, Japan
关键词
biomaterial; cell adhesion; detachment shear strength; murine fibroblast; microcantilever;
D O I
10.1016/S0142-9612(97)00248-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Affinity for cells is one of the important properties for biomaterials, because they are always used adjacent to living tissue. For the development of new biomaterials with superior biocompatibility, quantitative evaluation of the materials' affinity for cells is necessary. One of the methods to evaluate the materials' affinity for cells quantitatively is to measure the detachment force of an adherent cell on a material. In this study, a new system was developed to measure directly the shear force necessary to detach a cell from a material. Using a microcantilever, the detachment force was measured in the cell culture medium by applying a lateral load to the cell which adhered to the material. During the measurement, the cell was observed using an optical microscope and the image of the cell was recorded on a video tape through a CCD camera. The cell adhesive area before detaching the cell was measured by analyzing the obtained video image of the cell. Reproducibility of the measurement was demonstrated by repeating the measurement of the shear forces to detach murine fibroblasts 1,929 incubated for 24 h on glass. The average shear strength, which is a detachment force per unit cell adhesive area, is 530-750 Pa, varying with the day of cell preparation. However, the shear strengths of the cells seeded at the same time into separate dishes are corresponding well to each other. This fact suggests that it is possible to compare the materials' affinity for cells using this system if the cells were seeded at the same time onto different materials. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:871 / 879
页数:9
相关论文
共 20 条
[1]  
ENDO K, 1995, MAT JAPAN, V34, P1166
[2]  
FRANCIS GW, 1987, J CELL SCI, V87, P519
[3]   Quantification of cell adhesion using a spinning disc device and application to surface-reactive materials [J].
Garcia, AJ ;
Ducheyne, P ;
Boettiger, D .
BIOMATERIALS, 1997, 18 (16) :1091-1098
[4]   CELL-ADHESION TO A SERIES OF HYDROPHILIC-HYDROPHOBIC COPOLYMERS STUDIED WITH A SPINNING DISK APPARATUS [J].
HORBETT, TA ;
WALDBURGER, JJ ;
RATNER, BD ;
HOFFMAN, AS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (05) :383-404
[5]  
II I, 1985, BIOINDUSTRY, V2, P981
[6]   SURFACE MODIFICATION OF POLYMERS FOR MEDICAL APPLICATIONS [J].
IKADA, Y .
BIOMATERIALS, 1994, 15 (10) :725-736
[7]  
KATAOKA N, 1996, P 74 JSME FALL ANN M, P117
[8]  
KOKITA K, 1993, J JPN SOC DENTAL MAT, V12, P242
[9]   CELL-ADHESION TO FIBRONECTIN AND TENASCIN - QUANTITATIVE MEASUREMENTS OF INITIAL BINDING AND SUBSEQUENT STRENGTHENING RESPONSE [J].
LOTZ, MM ;
BURDSAL, CA ;
ERICKSON, HP ;
MCCLAY, DR .
JOURNAL OF CELL BIOLOGY, 1989, 109 (04) :1795-1805
[10]   Dynamic blood cell contact with biomaterials: Validation of a flow chamber system according to international standards [J].
Otto, M ;
Klein, CL ;
Kohler, H ;
Wagner, M ;
Rohrig, O ;
Kirkpatrick, CJ .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (03) :119-129