Effect of re-implanted particles from intramedullary reaming on mechanical properties and callus formation

被引:42
作者
Hammer, T. O. [1 ]
Wieling, R. [1 ]
Green, J. M. [1 ]
Suedkamp, N. P. [1 ]
Schneider, E. [1 ]
Mueller, C. A. [1 ]
机构
[1] AO Res Inst, CH-7270 Davos, Switzerland
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2007年 / 89B卷 / 11期
关键词
D O I
10.1302/0301-620X.89B11.18994
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study investigated the quality and quantity of healing of a bone defect following intramedullary reaming undertaken by two fundamentally different systems; conventional, using non-irrigated, multiple passes; or suction/irrigation, using one pass. The result of a measured re-implantation of the product of reaming was examined in one additional group. We used 24 Swiss mountain sheep with a mean tibial medullary canal diameter between 8 mm and 9 mm. An 8 mm 'napkin ring' defect was created at the mid-diaphysis. The wound was either surgically closed or occluded. The medullary cavity was then reamed to 11 mm. The Reamer/Irrigator/Aspirator (RIA) System was used for the reaming procedure in groups A (RIA and autofilling) and B (RIA, collected reamings filled up), whereas reaming in group C (Synream and autofilling) was performed with the Synream System. The defect was allowed to auto-fill with reamings in groups A and C, but in group B, the defect was surgically filled with collected reamings. The tibia was then stabilised with a solid locking Unreamed Humerus Nail (UHN), 9.5 mm in diameter. The animals were killed after six weeks. After the implants were removed, measurements were taken to assess the stiffness, strength and callus formation at the site of the defect. There was no significant difference between healing after conventional reaming or suction/irrigation reaming. A significant improvement in the quality of the callus was demonstrated by surgically placing captured reamings into the defect using a graft harvesting system attached to the aspirator device. This was confirmed by biomechanical testing of stiffness and strength. This study suggests it could be beneficial to fill cortical defects with reaming particles in clinical practice, if feasible.
引用
收藏
页码:1534 / 1538
页数:5
相关论文
共 27 条
[1]  
ALFRED R, 1984, SURG FORUM, V35, P523
[2]   Fat embolism and related effects during reamed and unreamed intramedullary nailing in a pig model [J].
Buttaro, M ;
Mocetti, E ;
Alfie, V ;
Paniego, G ;
Piñeiro, T .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (04) :239-244
[3]   Reamed versus unreamed femoral nails - A randomised, prospective trial [J].
Clatworthy, MG ;
Clark, DI ;
Gray, DH ;
Hardy, AE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :485-489
[4]  
Coles R E, 2000, J South Orthop Assoc, V9, P98
[5]   INTRACORTICAL CIRCULATION AFTER INTRAMEDULLARY REAMING WITH REDUCTION OF PRESSURE IN MEDULLARY CAVITY - A MICROANGIOGRAPHIC STUDY ON RABBIT TIBIA [J].
DANCKWAR.G ;
LORENZI, L ;
OLERUD, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (07) :1390-&
[6]  
Danckwardt-Lilliestrom G, 1970, Acta Orthop Scand Suppl, V134, P1
[7]  
Danckwardt-Lilliestrom G, 1969, Acta Orthop Scand Suppl, V128, P1
[8]  
Frolke J P, 2000, Acta Orthop Belg, V66, P337
[9]  
Frolke JPM, 2001, J TRAUMA, V50, P65
[10]   Heterotopic ossification: A comparison between reamed and unreamed femoral nailing [J].
Furlong, AJ ;
Giannoudis, PV ;
Smith, RM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (01) :9-14