Modelling the elastic scattering in diagnostic radiology:: the importance of structure form factors

被引:13
作者
Cardoso, SC
Gonçalves, OD
Schechter, H
Eichler, J
机构
[1] Univ Fed Rio de Janeiro, Inst Fis, BR-21945970 Rio De Janeiro, Brazil
[2] Tech Fachhsch, D-13347 Berlin, Germany
关键词
D O I
10.1088/0031-9155/48/13/304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The importance of structure form factors in describing elastic scattering in diagnostic radiology was studied through a Monte Carlo code built to reproduce scattering in large water samples. The code, developed by us, considers all relevant interactions, including multiple scattering and interference due to scattering by the liquid structure. Geometrical conditions and energies similar to those found in radiology were used. The secondary to primary radiation ratio using the usual free atom approximation and the structure form factor was obtained and both approaches were compared. Calculations of radiological parameters such as the angular distribution of photons incident on the detector and the fraction of scattered photons stopped by anti-scattering grids were also performed considering mammography, thorax and abdomen radiography conditions. The results have shown that S(beta)/P depends on the experimental set-up, being more important for low momentum transfers and sample sizes for which the multiple scattering is not expected to be significant, as in the case of mammography. It was also verified that large samples increase the probability of multiple scattering, masking the structure peak in S() and making the sample structure important just for relatively thin samples. Considering mammography-like geometry, the maximum of the S(beta)/P distribution considering structure form factors occurs around 15degrees while the correspondent maximum without considering the structure factors occurs around 10degrees for any sample thickness. S(beta)/P is almost independent of the irradiation field, with the maximum remaining at 15degrees and 10degrees for the SFF and FAFF, respectively. The cases studied in this paper stress some conditions in which it is mandatory to use SFF, but since it requires no further significant efforts, the SFF approach is recommended as a standard procedure when describing the elastic scattering process in radiology.
引用
收藏
页码:1907 / 1916
页数:10
相关论文
共 14 条
[1]   SOME PROPERTIES OF PHOTON SCATTERING IN WATER PHANTOMS IN DIAGNOSTIC-RADIOLOGY [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1986, 13 (06) :824-830
[2]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[3]   COHERENT SCATTER IN DIAGNOSTIC-RADIOLOGY [J].
JOHNS, PC ;
YAFFE, MJ .
MEDICAL PHYSICS, 1983, 10 (01) :40-50
[4]   SCATTERED RADIATION IN FAN BEAM IMAGING-SYSTEMS [J].
JOHNS, PC ;
YAFFE, M .
MEDICAL PHYSICS, 1982, 9 (02) :231-239
[5]   MONTE-CARLO CALCULATIONS OF X-RAY SCATTER DATA FOR DIAGNOSTIC-RADIOLOGY [J].
KALENDER, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (05) :835-849
[6]   RAYLEIGH-SCATTERING BY NEUTRAL ATOMS, 100-EV TO 10-MEV [J].
KISSEL, L ;
PRATT, RH ;
ROY, SC .
PHYSICAL REVIEW A, 1980, 22 (05) :1970-2004
[8]   CALCULATION OF X-RAY SINGLE SCATTERING IN DIAGNOSTIC-RADIOLOGY [J].
MORIN, LRM ;
BERROIR, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (07) :789-797
[9]  
NARTEN N, 1970, 4578 ORNL
[10]   COHERENT SCATTER IN RADIOGRAPHIC IMAGING - A MONTE-CARLO SIMULATION STUDY [J].
NEITZEL, U ;
KOSANETZKY, J ;
HARDING, G .