Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts

被引:43
作者
Das, RK
Li, Z
Perera, H
Williamson, JF
机构
[1] Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis
关键词
D O I
10.1088/0031-9155/41/6/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration energy. The purpose of this paper is to assess the accuracy of Monte Carlo photon transport (MCPT) simulation in modelling the absolute detector response as a function of detector geometry and photon energy. We have exposed two different sizes of TLD-100 (LiF chips) and p-type silicon diode detectors to calibrated Co-60, HDR source (Ir-192) and superficial x-ray beams. For the Scanditronix electron-field diode, the relative detector response, defined as the measured detector readings per measured unit of air kerma, varied from 38.46 V cGy(-1) (40 kVp beam) to 6.22 V cGy(-1) (Co-60 beam). Similarly for the large and small chips the same quantity varied from 2.08-3.02 nC cGy(-1) and 0.171-0.244 nC cGy(-1), respectively. Monte Carlo simulation was used to calculate the absorbed dose to the active volume of the detector per unit air kerma. If the Monte Carlo simulation is accurate, then the absolute detector response, which is defined as the measured detector reading per unit dose absorbed by the active detector volume, and is calculated by Monte Carlo simulation, should be a constant. For the diode, the absolute response is 5.86 +/- 0.15 (V cGy(-1)). For TLDs of size 3 x 3 x 1 mm(3) the absolute response is 2.47 +/- 0.07 (nC cGy(-1)) and for TLDs of 1 x 1 x 1 mm(3) it is 0.201 +/- 0.008 (nC cCy(-1)). From the above results we can conclude that the absolute response function of detectors (TLDs and diodes) is directly proportional to absorbed dose by the active volume of the detector and is independent of beam quality.
引用
收藏
页码:995 / 1006
页数:12
相关论文
共 30 条
[1]  
ANDERSON L, 1990, INTERSTITIAL BRACHYT
[2]  
[Anonymous], MED PHYS
[3]  
[Anonymous], 1983, MED PHYS, V10, P741
[4]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[5]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[6]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[7]   CALIBRATION OF IR-192 HIGH-DOSE-RATE AFTERLOADING SYSTEMS [J].
GOETSCH, SJ ;
ATTIX, FH ;
PEARSON, DW ;
THOMADSEN, BR .
MEDICAL PHYSICS, 1991, 18 (03) :462-467
[8]   MONTE-CARLO CALCULATION OF KERMA TO A POINT IN THE VICINITY OF MEDIA INTERFACES [J].
LI, ZF ;
WILLIAMSON, JF ;
PERERA, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12) :1825-1840
[9]   VOLUME-BASED GEOMETRIC MODELING FOR RADIATION TRANSPORT CALCULATIONS [J].
LI, ZF ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1992, 19 (03) :667-677
[10]   PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT [J].
LING, CC ;
YORKE, ED ;
SPIRO, IJ ;
KUBIATOWICZ, D ;
BENNETT, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11) :1747-1752