摘要
This paper provides an overview of recent advances in electrochemical sensors for industrial hygiene monitoring applications. Currently available instrument technologies as well as new devices under development are both exemplified. Progress in ruggedization and miniaturization of electroanalytical devices has led to significant improvements for on-site monitoring applications, e.g. in harsh environments and in biological monitoring. Sensor arrays and modified electrodes offer considerable promise for improved electrochemical sensing, i.e. through multi-species detection and enhanced selectivity. On-site electroanalytical detection and measurement in the field may become more widely used for applications in occupational health monitoring. Published by Elsevier B.V.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 113 条
[1]   Development and testing of HCl gas sensor for flue gas monitoring [J].
Ahmed, NN ;
Kale, GM ;
Kumar, RV ;
Fray, DJ .
SOLID STATE IONICS, 1996, 86-8 :1013-1016
[2]  
ALLEN H, 1989, ACS SYM SER, V403, P105
[3]   Influence of humidity an a potentiometric CO2 gas sensor using a combined electrolyte of sodium ion conducting glass and stabilized zirconia [J].
Aono, H ;
Supriyatno, H ;
Sadaoka, Y .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (09) :2981-2984
[4]   Analysis of organic compounds in air:: A review [J].
Aragón, P ;
Atienza, J ;
Climent, MD .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 30 (2-3) :121-151
[5]  
Ashley K, 2002, AM LAB, V34, P32
[6]   Ultrasonic extraction and field-portable anodic stripping voltammetric measurement of lead in dust wipe samples [J].
Ashley, K ;
Wise, TJ ;
Mercado, W ;
Parry, DB .
JOURNAL OF HAZARDOUS MATERIALS, 2001, 83 (1-2) :41-50
[7]   Ultrasonic extraction and portable anodic stripping voltammetric measurement of lead in paint, dust wipes, soil, and air: An interlaboratory evaluation [J].
Ashley, K ;
Song, RG ;
Esche, CA ;
Schlecht, PC ;
Baron, PA ;
Wise, TJ .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (05) :459-464
[8]   ELECTROANALYTICAL APPLICATIONS IN OCCUPATIONAL AND ENVIRONMENTAL-HEALTH [J].
ASHLEY, K .
ELECTROANALYSIS, 1994, 6 (10) :805-820
[9]   SOLUTION INFRARED SPECTROELECTROCHEMISTRY - A REVIEW [J].
ASHLEY, K .
TALANTA, 1991, 38 (11) :1209-1218
[10]  
Ashley K, 1998, FIELD ANAL CHEM TECH, V2, P39, DOI 10.1002/(SICI)1520-6521(1998)2:1<39::AID-FACT5>3.0.CO