Emerging biomedical sensing technologies and their applications

被引:111
作者
Coté, GL
Lec, RM
Pishko, MV
机构
[1] Texas A&M Univ, Dept Biomed Engn Program, College Stn, TX 77843 USA
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[3] Drexel Univ, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
[4] Penn State Univ, Dept Chem Engn, University Pk, PA 16802 USA
关键词
D O I
10.1109/JSEN.2003.814656
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent progress in biomedical sensing technologies has resulted in the development of several novel sensor products and new applications. Modern biomedical sensors developed with advanced microfabrication and signal processing techniques are becoming inexpensive, accurate, and reliable. A broad range of sensing mechanisms has significantly increased the number of possible target measurands that can be detected. The miniaturization of classical "bulky" measurement techniques has led to the realization of complex analytical systems, including such sensors as the BioChemLab-on-a-Chip. This rapid progress in miniature devices and instrumentation development will significantly impact the practice of medical care as well as future advances in the biomedical industry. Currently, electrochemical, optical, and acoustic wave sensing technologies have emerged as some of the most promising biomedical sensor technologies. In this paper, important features of these technologies, along with new developments and some of the applications, are presented.
引用
收藏
页码:251 / 266
页数:16
相关论文
共 136 条
[1]   Molecular imprinting: developments and applications in the analytical chemistry field [J].
Andersson, LI .
JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (01) :3-13
[2]   ACOUSTIC-WAVE BIOSENSORS [J].
ANDLE, JC ;
VETELINO, JF .
SENSORS AND ACTUATORS A-PHYSICAL, 1994, 44 (03) :167-176
[3]  
ARBERL F, 1994, SENSOR ACTUAT B-CHEM, V18, P271
[4]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[5]  
BALLANTAINE DS, 1997, ACOUSTIC WAVE SENSOR
[6]   Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :203-212
[7]   Development of immunosensors based on commercially available surface acoustic wave (SAW) devices [J].
Barié, N ;
Sigrist, H ;
Rapp, M .
ANALUSIS, 1999, 27 (07) :622-629
[8]   Covalent photolinker-mediated immobilization of an intermediate dextran layer to polymer-coated surfaces for biosensing applications [J].
Barie, N ;
Rapp, M ;
Sigrist, H ;
Ache, HJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :855-860
[9]   ISCHEMIC AREAS IN PERFUSED RAT HEARTS - MEASUREMENT BY NADH FLUORESCENCE PHOTOGRAPHY [J].
BARLOW, CH ;
CHANCE, B .
SCIENCE, 1976, 193 (4256) :909-910
[10]  
BARTORELLI AL, 1991, J AM COLL CARDIOL, V17, pB160