Computer-aided detection of colorectal polyps: Can it improve sensitivity of less-experienced readers? Preliminary findings

被引:56
作者
Baker, Mark E.
Bogoni, Luca
Obuchowski, Nancy A.
Dass, Chandra
Kendzierski, Renee M.
Remer, Erick M.
Einstein, David M.
Cathier, Pascal
Jerebko, Anna
Lakare, Sarang
Blum, Andrew
Caroline, Dina F.
Macari, Michael
机构
[1] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
[3] Temple Univ, Dept Radiol, Philadelphia, PA 19122 USA
[4] NYU, Sch Med, Dept Radiol, New York, NY USA
[5] Siemens Med Syst Inc, Malvern, PA USA
关键词
D O I
10.1148/radiol.2451061116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. Materials and Methods: The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polys. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to reevaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. Results: The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P = .0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review or CAD findings, the mean time was 3 minutes 38 seconds. Conclusion: Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers.
引用
收藏
页码:140 / 149
页数:10
相关论文
共 49 条
[1]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[2]   Pulmonary nodules: Automated detection on CT images with morphologic matching algorithm preliminary results [J].
Bae, KT ;
Kim, JS ;
Na, YH ;
Kim, KG ;
Kim, JH .
RADIOLOGY, 2005, 236 (01) :286-294
[3]   Computer-aided detection (CAD) in screening mammography: Sensitivity of commercial CAD systems for detecting architectural distortion [J].
Baker, JA ;
Rosen, EL ;
Lo, JY ;
Gimenez, EI ;
Welsh, R ;
Soo, MS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) :1083-1088
[4]   Computer-aided detection (CAD) for CT colonography: a tool to address a growing need [J].
Bogoni, L ;
Cathier, P ;
Dundar, M ;
Jerebko, A ;
Lakare, S ;
Liang, J ;
Periaswamy, S ;
Baker, ME ;
MacAri, M .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S57-S62
[5]   Computed tomographic colonography (virtual colonoscopy) - A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia [J].
Cotton, PB ;
Durkalski, VL ;
Benoit, PC ;
Palesch, YY ;
Mauldin, PD ;
Hoffman, B ;
Vining, DJ ;
Small, WC ;
Affronti, J ;
Rex, D ;
Kopecky, KK ;
Ackerman, S ;
Burdick, JS ;
Brewington, C ;
Turner, MA ;
Zfass, A ;
Wright, AR ;
Iyer, RB ;
Lynch, P ;
Sivak, MV ;
Butler, H .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (14) :1713-1719
[6]   Impact of computer-aided detection in a regional screening mammography program [J].
Cupples, TE ;
Cunningham, JE ;
Reynolds, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) :944-950
[7]   Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience [J].
Destounis, SV ;
DiNitto, P ;
Logan-Young, W ;
Bonaccio, E ;
Zuley, ML ;
Willison, KM .
RADIOLOGY, 2004, 232 (02) :578-584
[8]   A methodology for training and validating a CAD system and potential pitfalls [J].
Dundar, M ;
Fung, G ;
Bogoni, L ;
Macari, M ;
Megibow, A ;
Rao, B .
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 :1010-1014
[9]   Colorectal neoplasia screening with CT colonography in average-risk asymptomatic subjects: Community-based study [J].
Edwards, JT ;
Mendelson, RM ;
Fritschi, L ;
Foster, NM ;
Wood, C ;
Murray, D ;
Forbes, GM .
RADIOLOGY, 2004, 230 (02) :459-464
[10]   CT colonography: pitfalls and interpretation [J].
Fenlon, HM .