Sensitivity maps and system requirements for magnetic induction tomography using a planar gradiometer

被引:63
作者
Rosell, J
Casañas, R
Scharfetter, H
机构
[1] Univ Politecn Catalunya, Dept Engn Elect, ES-08034 Barcelona, Spain
[2] Graz Tech Univ, Inst Biomed Engn, A-8010 Graz, Austria
关键词
magnetic induction; electromagnetic tomography; bioimpedance; eddy currents; planar gradiometer;
D O I
10.1088/0967-3334/22/1/316
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We evaluated analytically and experimentally the performance of a planar gradiometer as a sensing element in a system for magnetic induction tomography. A system using an excitation coil and a planar gradiometer was compared against a system with two coils. We constructed one excitation coil, two different sensing elements and a high-resolution phase detector. The first sensor was a PCB square spiral coil with seven turns. The second sensor was a PCB planar gradiometer with two opposite square spirals of seven turns, with a distance between centres of 8 cm. Theoretical sensitivity maps were derived from basic equations and compared with experimental data obtained at 150 kHz. The experimental sensitivity maps were obtained measuring the perturbation produced by a brass sphere of 12 mm in empty space. The advantage of using a gradiometer is that it can be adjusted to give a minimum signal for homogeneous objects, while increasing the sensitivity to local perturbations of the conductivity. Results show that a system using a planar gradiometer as detector has less demanding requirements for the electronic system than a system using simple coils.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 13 条
[1]  
ALBRECHTSEN RA, 1995, PROCESS TOMOGRAPHY 1, P288
[3]   Magnetic induction tomography - A measuring system for biological tissues [J].
Griffiths, H ;
Stewart, WR ;
Gough, W .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :335-345
[4]  
Kaden H., 1959, WIRBELSTROEME SCHIRM, P290
[5]   Progress in realization of magnetic induction tomography [J].
Korjenevsky, AV ;
Cherepenin, VA .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :346-352
[6]  
MORTARELLI JR, 1980, IEEE T BIO-MED ENG, V27, P665, DOI 10.1109/TBME.1980.326677
[7]   TISSUE IMPEDANCE SPECTRA AND THE APPROPRIATE FREQUENCIES FOR EIT [J].
OSYPKA, M ;
GERSING, E .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A49-A55
[8]  
Peyton AJ, 1999, 1 WORLD C IND PROCES, V3, P306
[9]  
Ramli S., 1999, P 1 WORLD C IND PROC, P502
[10]   Inductively coupled wideband transceiver for bioimpedance spectroscopy (IBIS) [J].
Scharfetter, H ;
Ninaus, W ;
Puswald, B ;
Petrova, GI ;
Kovachev, D ;
Hutten, H .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :322-334