Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue

被引:75
作者
De Jaeger, K [1 ]
Hoogeman, MS [1 ]
Engelsman, M [1 ]
Seppenwoolde, Y [1 ]
Damen, EMF [1 ]
Mijnheer, BJ [1 ]
Boersma, LJ [1 ]
Lebesque, JV [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
关键词
lung inhomogeneity; dose-calculation algorithm; NTCP models; lung injury;
D O I
10.1016/S0167-8140(03)00195-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung dose (MLD) and the percentage of lung receiving > 20 Gy (V20). Published dose-effect relations for local perfusion changes and radiation pneumonitis were re-evaluated. Results: Evaluation of isodoses showed a consistent overestimation of the dose at the lung/tumor boundary by the EPL algorithm of about 10%. This overprediction of dose was also reflected in a consistent shift of the EPL DVHs for the lungs towards higher doses. The MLD, as determined by the EPL and CS algorithm, differed on average by 17 +/- 4.5% (+/- 1SD). For V20, the average difference was 12 +/- 5.7% (+/- 1SD). For both parameters, a strong correlation was found between the EPL and CS algorithms yielding a straightforward conversion procedure. Re-evaluation of the dose-effect relations showed that lung complications occur at a 12-14% lower dose. The values of the TD50 parameter for local perfusion reduction and radiation pneumonitis changed from 60.5 and 34.1 Gy to 51.1 and 29.2 Gy, respectively. Conclusions: A simple tissue inhomogeneity-correction algorithm like the EPL overestimates the dose to normal lung tissue. Dosimetric parameters for lung injury (e.g. MLD, V20) computed using both algorithms are strongly correlated making an easy conversion feasible. Dose-effect relations should be refitted when more accurate dose data is available. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 52 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[3]  
[Anonymous], 1993, 50 ICRU
[4]  
[Anonymous], 1999, 62 ICRU
[5]   The impact of electron transport on the accuracy of computed dose [J].
Arnfield, MR ;
Siantar, CH ;
Siebers, J ;
Garmon, P ;
Cox, L ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (06) :1266-1274
[6]   First results of a phase I/II dose escalation trial in non-small cell lung cancer using three-dimensional conformal radiotherapy [J].
Belderbos, JSA ;
De Jaeger, K ;
Heemsbergen, WD ;
Seppenwoolde, Y ;
Baas, P ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) :113-120
[7]  
Bentzen SM, 2000, INT J RADIAT BIOL, V76, P453, DOI 10.1080/095530000138448
[8]   DOSE-EFFECT RELATIONS FOR LOCAL FUNCTIONAL AND STRUCTURAL-CHANGES OF THE LUNG AFTER IRRADIATION FOR MALIGNANT-LYMPHOMA [J].
BOERSMA, LJ ;
DAMEN, EMF ;
DEBOER, RW ;
MULLER, SH ;
ROOS, CM ;
OLMOS, RAV ;
VANZANDWIJK, N ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :201-209
[9]   A NEW METHOD TO DETERMINE DOSE-EFFECT RELATIONS FOR LOCAL LUNG-FUNCTION CHANGES USING CORRELATED SPECT AND CT DATA [J].
BOERSMA, LJ ;
DAMEN, EMF ;
DEBOER, RW ;
MULLER, SH ;
OLMOS, RAV ;
HOEFNAGEL, CA ;
ROOS, CM ;
VANZANDWIJK, N ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :110-116
[10]   Recovery of overall and local lung function loss 18 months after irradiation for malignant lymphoma [J].
Boersma, LJ ;
Damen, EMF ;
deBoer, RW ;
Muller, SH ;
Olmos, RAV ;
vanZandwijk, N ;
Lebesque, JV .
JOURNAL OF CLINICAL ONCOLOGY, 1996, 14 (05) :1431-1441