A study on adaptive IMRT treatment planning using kV cone-beam CT

被引:163
作者
Ding, George X. [1 ]
Duggan, Dennis M. [1 ]
Coffey, Charles W. [1 ]
Deeley, Matthew [1 ]
Hallahan, Dennis E. [1 ]
Cmelak, Anthony [1 ]
Malcolm, Arnold [1 ]
机构
[1] Vanderbilt Univ, Sch Med, Dept Radiat Oncol, Vanderbilt Ingram Canc Ctr,TVC, Nashville, TN 37232 USA
关键词
cone-beam CT; hounsfield units; adaptive radiotherapy; IMRT; head and neck cancer; prostate cancer;
D O I
10.1016/j.radonc.2007.06.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Changes in tumor size during the course of radiotherapy warrant performing adaptive radiotherapy (ART). This work investigates the feasibility and usefulness of acquiring on-board cone-beam CT (CBCT) for ART for patients with bulky head and neck tumors treated with IMRT and for prostate patients with potentially significant target position variations during the treatment course. Materials and methods: A phantom designed for CT quality assurance was used to compare the dosimetric and geometric accuracy between conventional CT and CBCT from a linear accelerator's on-board imager. Patient planning CT and CBCT images were acquired before treatment and at mid-course. The IMRT plans made on the CT were applied to the CBCT and dose-volume histograms were calculated. Results: In both phantom and patient studies, the dose-volume histograms (DVHs) based on CBCT images were in excellent agreement with DVHs based on planning CT images. Minimum, maximum and mean doses agreed very well. In a patient study, doses for targets and normal tissues from the same IMRT plans calculated on CBCT images agreed within 1-3% with those calculated on planning CT images. Conclusions: CBCT images can be used to accurately predict dosimetric results. It is feasible to use CBCT to determine dosimetric consequences resulting from tumor shrinkage and patient geometry changes. An additional planning CT may be necessary to perform IMRT re-planning at present in order to accurately delineate tumor and organs. The CBCT has potential to become a very useful tool for on-line ART. (c) 2007 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 85 (2007) 116-125.
引用
收藏
页码:116 / 125
页数:10
相关论文
共 26 条
[1]  
[Anonymous], 2006, CATPH 500 600 MAN
[2]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[3]  
BATHO H F, 1964, J Can Assoc Radiol, V15, P79
[4]   A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: Analysis of chronic toxicity [J].
Brabbins, D ;
Martinez, A ;
Yan, D ;
Lockman, D ;
Wallace, M ;
Gustafson, G ;
Chen, P ;
Vicini, F ;
Wong, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (02) :400-408
[5]  
CHENCHARICK JD, 1983, CANCER, V51, P811, DOI 10.1002/1097-0142(19830301)51:5<811::AID-CNCR2820510511>3.0.CO
[6]  
2-M
[7]   Accurate technique for complete geometric calibration of cone-beam computed tomography systems [J].
Cho, YB ;
Moseley, DJ ;
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (04) :968-983
[8]  
DONALDSON SS, 1979, CANCER, V43, P2036, DOI 10.1002/1097-0142(197905)43:5+<2036::AID-CNCR2820430712>3.0.CO
[9]  
2-7
[10]   A performance comparison of flat-panel imager-based MV and kV cone-beam CT [J].
Groh, BA ;
Siewerdsen, JH ;
Drake, DG ;
Wong, JW ;
Jaffray, DA .
MEDICAL PHYSICS, 2002, 29 (06) :967-975