A temperature insensitive quartz microbalance

被引:12
作者
Pierce, DE [1 ]
Kim, Y
Vig, JR
机构
[1] USA, Res Lab, Natl Res Council, Wayne, NJ 07470 USA
[2] William Patterson Univ, Dept Chem, Wayne, NJ 07470 USA
[3] USA, Commun Elect Command, Ctr Res Dev & Engn, Ft Monmouth, NJ 07703 USA
关键词
D O I
10.1109/58.726449
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Mass deposition onto a microbalance is generally accompanied by a temperature change. By measuring a single frequency only, it is not possible to separate the frequency change due to mass change from that due to temperature change. In the temperature insensitive microbalance technique, measurements of two frequencies, the fundamental mode and third overtone frequencies of an SC-cut resonator, yield two equations with two unknowns. This allows the separation of mass change effects from temperature change effects. Dual mode excitation can be used for highly accurate resonator self-temperature sensing over wide temperature ranges. SC-cut resonators are also thermal transient compensated. These unique properties allowed the development of a temperature compensated microbalance that is highly sensitive to mass changes, which can be used in rapidly changing thermal environments, over wide temperature ranges, and which requires neither temperature control nor a thermometer other than the resonator. To demonstrate the performance of this microbalance, SC-cut resonators were coated with thin polymethylmethacrylate (PMMA) photoresist films then placed into a UV-ozone cleaning chamber that initially was at about 20 degrees C. When the UV lamp was turned on, the UV-ozone removed PMMA from the surfaces while the chamber temperature rose to about 60 degrees C. The frequency changes due to mass changes could be accurately determined, independently of the frequency changes due to temperature changes.
引用
收藏
页码:1238 / 1245
页数:8
相关论文
共 25 条
[1]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[2]  
Ballato A., 1978, Proceedings of the 32nd Annual Symposium on Frequency Control 1978, P180
[3]  
BALLATO A, 1980, P 34 ANN FREQ CONTR, P431
[4]  
Ballato A., 1997, PHYS ACOUSTICS, VXIII
[5]   IMPROVED QUARTZ CRYSTAL MICROBALANCE TECHNIQUE [J].
BENES, E .
JOURNAL OF APPLIED PHYSICS, 1984, 56 (03) :608-626
[6]   A DUAL-MODE THICKNESS-SHEAR QUARTZ PRESSURE SENSOR [J].
BESSON, RJ ;
BOY, JJ ;
GLOTIN, B ;
JINZAKI, Y ;
SINHA, B ;
VALDOIS, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :584-591
[7]   FREQUENCY-OUTPUT FORCE SENSOR USING A MULTIMODE DOUBLY ROTATED QUARTZ RESONATOR [J].
DULMET, B ;
BOURQUIN, R ;
SHIBANOVA, N .
SENSORS AND ACTUATORS A-PHYSICAL, 1995, 48 (02) :109-116
[8]  
EerNisse E. P., 1975, Proceedings of the 29th Annual Frequency Control Symposium, P1
[9]   SURVEY OF QUARTZ BULK RESONATOR SENSOR TECHNOLOGIES [J].
EERNISSE, EP ;
WARD, RW ;
WIGGINS, RB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (03) :323-330
[10]   Draft revision of IEEE STD 1139-1988 Standard Definitions of Physical Quantities for Fundamental Frequency and Time Metrology - Random instabilities [J].
FerrePikal, ES ;
Vig, JR ;
Camparo, JC ;
Cutler, LS ;
Maleki, L ;
Riley, WJ ;
Stein, SR ;
Thomas, CE ;
Walls, FL ;
White, JD .
PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1997, :338-357