A novel method to compensate for different amplification efficiencies between patient DNA samples in quantitative real-time PCR

被引:256
作者
Meijerink, J
Mandigers, C
van de Locht, L
Tönnissen, E
Goodsaid, F
Raemaekers, J
机构
[1] Erasmus Univ, Sophia Childrens Hosp, Dept Pediat, Div Hematol Oncol, Rotterdam, Netherlands
[2] Univ Nijmegen Hosp, Dept Hematol, NL-6500 HB Nijmegen, Netherlands
[3] Univ Nijmegen Hosp, Cent Hematol Lab, NL-6500 HB Nijmegen, Netherlands
[4] Appl Biosyst Inc, Foster City, CA 94404 USA
关键词
D O I
10.1016/S1525-1578(10)60652-6
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Quantification of residual disease by real-time polymerase chain reaction (PCR) will become a pivotal tool in the development of patient-directed therapy, In recent years, various protocols to quantify minimal residual. disease in leukemia or lymphoma patients have been developed. These assays assume that PCR efficiencies are equal for all samples, Determining t(14;18) and albumin reaction efficiencies for sixteen follicular lymphoma patient samples revealed higher efficiencies for blood samples than for lymph node samples in general, However, within one sample both reactions had equivalent efficiencies. Differences in amplification efficiencies between patient samples (low efficiencies) and the calibrator in quantitative analyses result in the underestimation of residual disease in patient samples whereby the weakest positive patient samples are at highest error. Based on these findings for patient samples, the efficiency compensation control was developed. This control includes two reference reactions in a multiplex setting, specific for the p-actin and albumin housekeeping genes that are present in a constant ratio within DNA templates. The difference in threshold cycle values for both reference reactions, ie, the Delta Ct(2) value, is dependent on the amplification efficiency, and is used to compensate for efficiency differences between patient samples and the calibrator. The beta -actin reference reaction is also used to normalize for DNA input. Furthermore, the efficiency compensation control facilitates identification of patient samples that are so contaminated with PCR inhibitory compounds that different amplification reactions are affected to a different extent. Accurate quantitation of residual disease in these samples is therefore impossible with the current quantitative real-time PCR protocols. Identification and exclusion of these inadequate samples will be of utmost importance in quantitative retrospective studies, but even more so, in future molecular diagnostic analyses.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 27 条
  • [1] AKANE A, 1994, J FORENSIC SCI, V39, P362
  • [2] Bélec L, 1998, MUSCLE NERVE, V21, P1064, DOI 10.1002/(SICI)1097-4598(199808)21:8<1064::AID-MUS11>3.0.CO
  • [3] 2-U
  • [4] BEUTLER E, 1990, BIOTECHNIQUES, V9, P166
  • [5] THERMOSTABLE DNA-POLYMERASE CHAIN AMPLIFICATION OF T(14-18) CHROMOSOME BREAKPOINTS AND DETECTION OF MINIMAL RESIDUAL DISEASE
    CRESCENZI, M
    SETO, M
    HERZIG, GP
    WEISS, PD
    GRIFFITH, RC
    KORSMEYER, SJ
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (13) : 4869 - 4873
  • [6] Erlich H.A., 1989, PCR TECHNOLOGY PRINC
  • [7] A novel method for real time quantitative RT PCR
    Gibson, UEM
    Heid, CA
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 995 - 1001
  • [8] ANALYSIS OF CYTOKINE MESSENGER-RNA AND DNA - DETECTION AND QUANTITATION BY COMPETITIVE POLYMERASE CHAIN-REACTION
    GILLILAND, G
    PERRIN, S
    BLANCHARD, K
    BUNN, HF
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (07) : 2725 - 2729
  • [9] Effect of highly fragmented DNA on PCR
    Golenberg, EM
    Bickel, A
    Weihs, P
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (24) : 5026 - 5033
  • [10] Real time quantitative PCR
    Heid, CA
    Stevens, J
    Livak, KJ
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 986 - 994