Direct comparison of diagnostic performance of transient elastography in patients with chronic hepatitis B and chronic hepatitis C

被引:133
作者
Cardoso, Ana-Carolina [1 ,2 ]
Carvalho-Filho, Roberto J. [1 ,2 ,3 ]
Stern, Christiane [1 ,2 ]
Dipumpo, Alexandrine [1 ,2 ]
Giuily, Nathalie [1 ,2 ]
Ripault, Marie-Pierre [1 ,2 ]
Asselah, Tarik [1 ,2 ]
Boyer, Nathalie [1 ,2 ]
Lada, Olivier [1 ,2 ]
Castelnau, Corinne [1 ,2 ]
Martinot-Peignoux, Michelle [1 ,2 ]
Valla, Dominique-Charles [1 ,2 ]
Bedossa, Pierre [4 ,5 ]
Marcellin, Patrick [1 ,2 ]
机构
[1] Univ Paris 07, Serv Hepatol, Hop Beaujon, F-92110 Clichy, France
[2] Univ Paris 07, Hop Beaujon, APHP, INSERM U773 CRB3, F-92110 Clichy, France
[3] Univ Fed Sao Paulo, Hosp Sao Paulo, Hepatitis Sect, Div Gastroenterol, Sao Paulo, Brazil
[4] Univ Paris 07, Serv Anatomopathol, Hop Beaujon, F-92110 Clichy, France
[5] Univ Paris 07, Hop Beaujon, APHP, INSERM U773 CRB3, F-92110 Clichy, France
关键词
cirrhosis; hepatitis B; hepatitis C; liver fibrosis; liver stiffness; transient elastography; LIVER STIFFNESS MEASUREMENT; NONINVASIVE ASSESSMENT; NATURAL-HISTORY; FIBROSIS; BIOPSY; CIRRHOSIS; DISEASE; INFECTION; FIBROTEST;
D O I
10.1111/j.1478-3231.2011.02660.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/ Aims: Accuracy of transient elastography (TE) in hepatitis B virus (HBV) infection has not been well established. We aimed to compare the performances of TE for the assessment of liver fibrosis in patients with chronic HBV or hepatitis C virus (HCV) infection. A secondary analysis was performed to assess whether or not alanine aminotransferase (ALT) levels would impact on the accuracy of TE. Methods: This cross-sectional study, carried out in a single centre, included treatment-naive patients with compensated chronic HBV or HCV infection, consecutively admitted between 2006 and 2008 for a liver biopsy and TE measurement on the same day. Results: A total of 202 HBV patients and 363 HCV subjects were evaluated. Overall diagnostic accuracy of TE in the HBV group was comparable to that observed in HCV patients [area under the receiver-operating characteristics (AUROCs) 0.867 +/-0.026 vs. 0.868 +/-0.019 for predicting F +/-2, P = 0.975; 0.902 +/-0.029 vs. 0.894 +/-0.020 for F +/-3, P = 0.820; and 0.935 +/-0.024 vs. 0.947 +/-0.027 for F4, P = 0.740 respectively]. TE exhibited comparable accuracies, sensitivities, specificities, predictive values and likelihood ratios in HBV and HCV groups. AUROC analysis showed no influence of ALT levels on the performance of TE in HBV individuals. ALT-specific cut-off values did not exhibit significantly higher diagnostic performances for predicting fibrosis in HBV patients with elevated ALT. Conclusions: In HBV patients, TE measurement accurately predicts the absence or presence of significant fibrosis, advanced fibrosis or cirrhosis and shows similar performances as compared to HCV patients. The use of TE cut-off values adjusted to ALT level did not improve performances for estimating liver fibrosis in HBV patients.
引用
收藏
页码:612 / 621
页数:10
相关论文
共 27 条
[1]   Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C [J].
Arena, U. ;
Vizzutti, F. ;
Abraldes, J. G. ;
Corti, G. ;
Stasi, C. ;
Moscarella, S. ;
Milani, S. ;
Lorefice, E. ;
Petrarca, A. ;
Romanelli, R. G. ;
Laffi, G. ;
Bosch, J. ;
Marra, F. ;
Pinzani, M. .
GUT, 2008, 57 (09) :1288-1293
[2]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[3]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[4]   Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[5]   Early detection in routine clinical practice of cirrhosis and oesophageal varices in chronic hepatitis C: Comparison of transient elastography (FibroScan) with standard laboratory tests and non-invasive scores [J].
Castera, Laurent ;
Le Bail, Brigitte ;
Roudot-Thoraval, Francoise ;
Bernard, Pierre-Henri ;
Foucher, Juliette ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
JOURNAL OF HEPATOLOGY, 2009, 50 (01) :59-68
[6]   Alanine aminotransferase-based algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B [J].
Chan, H. L. -Y. ;
Wong, G. L. -H. ;
Choi, P. C. -L. ;
Chan, A. W. -H. ;
Chim, A. M. -L. ;
Yiu, K. K. -L. ;
Chan, F. K. -L. ;
Sung, J. J. -Y. ;
Wong, V. W. -S. .
JOURNAL OF VIRAL HEPATITIS, 2009, 16 (01) :36-44
[7]   Transient elastography: a new surrogate marker of liver fibrosis influenced by major changes of transaminases [J].
Coco, B. ;
Oliveri, F. ;
Maina, A. M. ;
Ciccorossi, P. ;
Sacco, R. ;
Colombatto, P. ;
Bonino, F. ;
Brunetto, M. R. .
JOURNAL OF VIRAL HEPATITIS, 2007, 14 (05) :360-369
[8]   Impact of liver biopsy size on histological evaluation of chronic viral hepatitis: the smaller the sample, the milder the disease [J].
Colloredo, G ;
Guido, M ;
Sonzogni, A ;
Leandro, G .
JOURNAL OF HEPATOLOGY, 2003, 39 (02) :239-244
[9]   Natural history and prognostic indicators of survival in cirrhosis: A systematic review of 118 studies [J].
D'Amico, G ;
Garcia-Tsao, G ;
Pagliaro, L .
JOURNAL OF HEPATOLOGY, 2006, 44 (01) :217-231
[10]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845