Matching dicrotic notch and mean pulmonary artery pressures: Implications for effective arterial elastance
被引:37
作者:
Chemla, D
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Chemla, D
Hebert, JL
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Hebert, JL
Coirault, C
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Coirault, C
Salmeron, S
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Salmeron, S
Zamani, K
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Zamani, K
Lecarpentier, Y
论文数: 0引用数: 0
h-index: 0
机构:UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
Lecarpentier, Y
机构:
[1] UNIV PARIS 11, HOP BICETRE, SERV PHYSIOL CARDIORESP, F-94275 LE KREMLIN BICETRE, FRANCE
[2] UNIV PARIS 11, HOP BICETRE, SERV MED INTERNE, F-94275 LE KREMLIN BICETRE, FRANCE
来源:
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY
|
1996年
/
271卷
/
04期
关键词:
end systole;
ventricular-arterial coupling;
stroke volume;
right ventricle;
Valsalva maneuver;
D O I:
10.1152/ajpheart.1996.271.4.H1287
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
It has been suggested that pulmonary artery pressure at the end of ejection is close to mean pulmonary artery pressure, thus contributing to the optimization of external power from the right ventricle. We tested the hypothesis that dicrotic notch and mean pulmonary artery pressures could be of similar magnitude in 15 men (50 +/- 12 yr) referred to our laboratory for diagnostic right and left heart catheterization. Beat-to-beat relationships between dicrotic notch and mean pulmonary artery pressures were studied 1) at rest over 10 consecutive beats and 2) in 5 patients during the Valsalva maneuver (178 beats studied). At rest, there was no difference between dicrotic notch and mean pulmonary artery pressures (21.8 +/- 12.0 vs. 21.9 +/- 11.1 mmHg. There was a strong linear relationship between dicrotic notch and mean pressures 1) over the 10 consecutive beats studied in each patient (mean r = 0.93), 2) over the 150 resting beats (r = 0.99), and 3) during the Valsalva maneuver in each patient (r = 0.98-0.99) and in the overall beats (r = 0.99). The difference between dicrotic notch and mean pressures was -0.1 +/- 1.7 mmHg at rest and -1.5 +/- 2.3 mmHg during the Valsalva maneuver. Substitution of the mean pulmonary artery pressure by the dicrotic notch pressure in the standard formula of the pulmonary vascular resistance (PVR) resulted in an equation relating linearly end-systolic pressure and stroke volume. The slope of this relation had the dimension of a volume elastance (in mmHg/ml), a simple estimate of volume elastance being obtained as 1.06(PVR/T), where T is duration of the cardiac cycle. In conclusion, dicrotic notch pressure was of similar magnitude as mean pulmonary artery pressure. These results confirmed our primary hypothesis and indicated that human pulmonary artery can be treated as if it is an elastic chamber with a volume elastance of 1.06(PVR/T).