Determination of trace metals in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry

被引:93
作者
Hirata, S
Ishida, Y
Aihara, M
Honda, K
Shikino, O
机构
[1] Chugoku Natl Ind Res Inst, Hiroshima 7370197, Japan
[2] Kinki Univ, Higashihiroshima 7392116, Japan
[3] Perkin Elmer Japan Co Ltd, Suita, Osaka 5640051, Japan
关键词
inductively coupled plasma mass spectrometry; Muromac A-1; trace elements; seawater; on-line column preconcentration;
D O I
10.1016/S0003-2670(01)00859-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A home made column of commercially available imminodiacetic functional group resin, Muromac A-1 was used to separate and concentrate trace metals (Al, V, MII, Co, Ni, Cu, Zn, Mo, Cd, Pb and U) from seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the determination of trace metals in seawater. S ample solutions (adjust ed to pH 5.0) passed through the column, after washing the column with water, the adsorbed metals were subsequently eluted into the plasma with 0.7 M nitric acid. Calibration curves were accomplished by means of purified artificial seawater with a sample loading time of 120 s. Detection limits of the trace metals in the artificial seawater were 0.007 for Al, 0.011 for V, 0.007 for Mn, 0.014 for Co, 0.029 for Ni, 0.099 for Cu, 0.076 for Zn, 0.007 fur Mo, 0.010 for Cd, 0.007 for Pb and 0.001 ng ml(-1) for U, respectively, as the concentrations of analyte metals corresponding to three times (3 sigma) the standard deviation of blank signal intensities by eight replicate measurements. The precision was less than +/-5.4% for 11 elements and one sample can be processed in 7 ml and 8 min. The proposed method was verified by the analysis of two reference standard materials of seawater CASS-3 and NASS-4. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 21 条
[1]   DETERMINATION OF IRON AND 10 OTHER TRACE-ELEMENTS IN THE OPEN OCEAN SEAWATER REFERENCE MATERIAL NASS-3 BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
AKATSUKA, K ;
MCLAREN, JW ;
LAM, JW ;
BERMAN, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :889-894
[2]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[3]   PRECONCENTRATION AND DETERMINATION OF TRACE CHROMIUM(III) BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA/ATOMIC EMISSION-SPECTROMETRY [J].
COX, AG ;
MCLEOD, CW .
ANALYTICA CHIMICA ACTA, 1986, 179 :487-490
[4]   RAPID SEQUENTIAL DETERMINATION OF CHROMIUM(III) - CHROMIUM(VI) BY FLOW-INJECTION ANALYSIS - INDUCTIVELY COUPLED PLASMA ATOMIC-EMISSION SPECTROMETRY [J].
COX, AG ;
COOK, IG ;
MCLEOD, CW .
ANALYST, 1985, 110 (04) :331-333
[5]   AN EFFICIENT FLOW-INJECTION SYSTEM WITH ONLINE ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :23-39
[6]  
FANG ZL, 1984, ANAL CHIM ACTA, V164, P41
[7]  
FANG ZL, 1993, FLOW INJECTION SEPAR, P103
[8]   SENSITIVITY ENHANCEMENTS FOR FLOW-INJECTION ANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HARTENSTEIN, SD ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :21-25
[9]   Determination of chromium(III) and total chromium in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Honda, K ;
Shikino, O ;
Maekawa, N ;
Aihara, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1089-1099
[10]   MASS-SPECTROMETRY OF INDUCTIVELY COUPLED PLASMAS [J].
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :A97-&