Reliability of nucleic acid amplification methods for detection of Chlamydia trachomatis in urine:: Results of the first international collaborative quality control study among 96 laboratories

被引:32
作者
Verkooyen, RP
Noordhoek, GT
Klapper, PE
Reid, J
Schirm, J
Cleator, GM
Ieven, M
Hoddevik, G
机构
[1] Publ Hlth Lab, NL-8900 JA Leeuwarden, Netherlands
[2] Erasmus MC, Dept Med Microbiol & Infect Dis, Rotterdam, Netherlands
[3] Reg Publ Hlth Lab, Groningen, Netherlands
[4] Publ Hlth Lab, Leeds, W Yorkshire, England
[5] ChimaeraBio, Glasgow, Lanark, Scotland
[6] Univ Manchester, Manchester, Lancs, England
[7] Univ Antwerp UIA, Dept Microbiol, B-2020 Antwerp, Belgium
[8] Natl Inst Publ Hlth, Oslo, Norway
关键词
D O I
10.1128/JCM.41.7.3013-3016.2003
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The first European Quality Control Concerted Action study was organized to assess the ability of laboratories to detect Chlamydia trachomatis in a panel of urine samples by nucleic acid amplification tests (NATs). The panel consisted of lyophilized urine samples, including three negative, two strongly positive, and five weakly positive samples. Ninety-six laboratories in 22 countries participated with a total of 102 data sets. Of 204 strongly positive samples 199 (97.5%) were correctly reported, and of 506 weakly positive samples 466 (92.1%) were correctly reported. In 74 (72.5%) data sets correct results were reported on all samples, and 17 data sets (16.7%) showed either one false-negative or one false-positive result. In another 11 data sets, two or more incorrect results were reported, and two data sets reported a false-positive result on one negative sample. The Roche COBAS Amplicor test was performed in 44 (43%) data sets, the Abbott LCx assay was performed in 31 (30%) data sets, the Roche Amplicor manual assay was performed in 9 (9%) data sets, an in-house PCR was performed in 9 (9%) data sets, the Becton Dickinson ProbeTec ET assay was performed in 5 (4.9%) data sets, and the GenProbe TMA assay was performed in 4 (3.9%) data sets. The results of the Roche Amplicor manual (95.6% correct), COBAS Amplicor (97.0%), and Abbott LCx (94.8%) tests were comparable (P = 0.48). The results with the in-house PCR, BD ProbeTec ET, and GenProbe TMA tests were reported correctly in 88.6, 98, and 92.5% of the tests, respectively. Freeze-drying of clinical urine specimens proved to be a successful method for generating standardized, stable, and easy-to-transport samples for the detection of C. trachomatis by using NATs. Although the results, especially the specificity, for this proficiency panel were better than most quality control studies, sensitivity problems occurred frequently, underlining the need for good laboratory practice and reference reagents to monitor the performance of these assays.
引用
收藏
页码:3013 / 3016
页数:4
相关论文
共 17 条
[1]   False-negative results of a ligase chain reaction assay to detect Chlamydia trachomatis due to inhibitors in urine [J].
Berg, ES ;
Anestad, G ;
Moi, H ;
Storvold, G ;
Skaug, K .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (10) :727-731
[2]   ASYMPTOMATIC CHLAMYDIA-TRACHOMATIS INFECTIONS IN TEENAGE MALES [J].
BRADY, M ;
BAKER, C ;
NEINSTEIN, LS .
JOURNAL OF ADOLESCENT HEALTH, 1988, 9 (01) :72-75
[3]   Urinary inhibitors of polymerase chain reaction and ligase chain reaction and testing of multiple specimens may contribute to lower assay sensitivities for diagnosing Chlamydia trachomatis infected women [J].
Chernesky, MA ;
Jang, D ;
Sellors, J ;
Luinstra, K ;
Chong, S ;
Castriciano, S ;
Mahony, JB .
MOLECULAR AND CELLULAR PROBES, 1997, 11 (04) :243-249
[4]   International collaborative study on the second EUROHEP HCV-RNA reference panel [J].
Damen, M ;
Cuypers, HTM ;
Zaaijer, HL ;
Reesink, HW ;
Schaasberg, WP ;
Gerlich, WH ;
Niesters, HGM ;
Lelie, PN .
JOURNAL OF VIROLOGICAL METHODS, 1996, 58 (1-2) :175-185
[5]   CHLAMYDIA-TRACHOMATIS, TUBAL DISEASE AND THE INCIDENCE OF SYMPTOMATIC AND ASYMPTOMATIC INFECTION FOLLOWING HYSTEROSALPINGOGRAPHY [J].
FORSEY, JP ;
CAUL, EO ;
PAUL, ID ;
HULL, MGR .
HUMAN REPRODUCTION, 1990, 5 (04) :444-447
[6]   Comparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine [J].
Goessens, WHF ;
Mouton, JW ;
vanderMeijden, WI ;
Deelen, S ;
vanRijsoortVos, TH ;
Toom, NLD ;
Verbrugh, HA ;
Verkooyen, RP .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) :2628-2633
[7]  
Karber G., 1931, ARCH EXP PATH PHARMA, V162, P480, DOI [DOI 10.1007/BF01863914, 10.1007/BF01863914]
[8]   Urine specimens from pregnant and nonpregnant women inhibitory to amplification of Chlamydia trachomatis nucleic acid by PCR, ligase chain reaction, and transcription-mediated amplification:: Identification of urinary substances associated with inhibition and removal of inhibitory activity [J].
Mahony, J ;
Chong, S ;
Jang, D ;
Luinstra, K ;
Faught, M ;
Dalby, D ;
Sellors, J ;
Chernesky, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (11) :3122-3126
[9]   Symptoms and signs in single and mixed genital infections [J].
Mårdh, PA ;
Tchoudomirova, K ;
Elshibly, S ;
Hellberg, D .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1998, 63 (02) :145-152
[10]   Reliability of nucleic acid amplification for detection of Mycobacterium tuberculosis: An international collaborative quality control study among 30 laboratories [J].
Noordhoek, GT ;
vanEmbden, JDA ;
Kolk, AHJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (10) :2522-2525