Apparent loss of urinary albumin during long-term frozen storage: HPLC vs immunonephelometry

被引:45
作者
Brinkman, Jacoline W.
De Zeeuw, Dick
Lambers Heerspink, Hiddo J.
Gansevoort, Ronald T.
Kema, Ido P.
de Jong, Paul E.
Bakker, Stephan J. L.
机构
[1] Univ Groningen, Med Ctr, Dept Internal Med, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Med Ctr, Dept Clin Pharmacol, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Med Ctr, Div Nephrol, NL-9700 RB Groningen, Netherlands
[4] Univ Groningen, Med Ctr, Dept Pathol & Lab Med, NL-9700 RB Groningen, Netherlands
关键词
D O I
10.1373/clinchem.2007.088823
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Urinary albumin detection by immuno-nephelometry is decreased by -30% in samples that have been frozen at -20 degrees C. An HPLC method for assessment of urinary albumin that detects immunoreactive and immunochemically nonreactive albumin has been introduced as an alternative to immunonephelometry. We investigated whether this technique is affected by sample temperature, particularly freezing. Methods: Urine samples (n = 295) were collected from the general population (Prevention of Renal and Vascular End-Stage Disease Study). Samples were assessed by both immunonephelometry and HPLC when fresh and after storage at -20 degrees C for 4, 8, and 12 months and at -80 degrees C for 12 months. Results: With immunonephelometry, storage for 4, 8, and 12 months at -20 degrees C resulted in mean (SD) urine albumin changes of -21% (29%), -28% (29%), and -34% (31) (P < 0.001 for trend). Storage at -80 degrees C resulted in a 5% (19%) change after 12 months of storage (not significant). With HPLC, storage for 4, 8, and 12 months at -20 degrees C resulted in urine albumin changes of -33% (28%), -43% (24%), and -55% (21%; P < 0.001 vs immunonephelometry). Storage at - 80 degrees C resulted in a -29% (29%) change (P < 0.001 vs immunonephelometry). Conclusion: Loss of albumin after freezing urine depends not only on freezing temperature but also on detection method. Detection of albumin by immuno- nephelometry appears to be significantly less influenced by freezing than detection by HPLC. Storage at -80 degrees C appears to prevent loss when using immunonephelometry, whereas HPLC still shows considerable loss even when urine is frozen at -80 degrees C. We propose that for reliable measurement of urine albumin, fresh samples should be used. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1520 / 1526
页数:7
相关论文
共 18 条
[1]   Urinary albumin excretion as a predictor of the development of hypertension in the general population [J].
Brantsma, Auke H. ;
Bakker, Stephan J. L. ;
de Zeeuw, Dick ;
de Jong, Paul E. ;
Gansevoort, Ronald T. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (02) :331-335
[2]   Prolonged frozen storage of urine reduces the value of albuminuria for mortality prediction [J].
Brinkman, Jacoline W. ;
de Zeeuw, Dick ;
Gansevoort, Ronald T. ;
Duker, Jacko J. ;
Kema, Ido P. ;
de Jong, Paul E. ;
Bakker, Stephan J. L. .
CLINICAL CHEMISTRY, 2007, 53 (01) :153-154
[3]   Falsely low urinary albumin concentrations after prolonged frozen storage of urine samples [J].
Brinkman, JW ;
de Zeeuw, D ;
Duker, JJ ;
Gansevoort, RT ;
Kema, IP ;
Hillege, HL ;
de Jong, PE ;
Bakker, SJL .
CLINICAL CHEMISTRY, 2005, 51 (11) :2181-2183
[4]   Which method for quantifying urinary albumin excretion gives what outcome? A comparison of immunonephelometry with HPLC [J].
Brinkman, JW ;
Bakker, SJL ;
Gansevoort, RT ;
Hillege, HL ;
Kema, IP ;
Gans, ROB ;
De Jong, PE ;
De Zeeuw, D .
KIDNEY INTERNATIONAL, 2004, 66 :S69-S75
[5]   The analysis and characterisation of immuno-unreactive urinary albumin in healthy volunteers [J].
Clavant, SP ;
Sastra, SA ;
Osicka, TM ;
Comper, WD .
CLINICAL BIOCHEMISTRY, 2006, 39 (02) :143-151
[6]   Earlier detection of micro albuminuria in diabetic patients using a new urinary albumin assay [J].
Comper, WD ;
Osicka, TM ;
Clark, M ;
MacIsaac, RJ ;
Jerums, G .
KIDNEY INTERNATIONAL, 2004, 65 (05) :1850-1855
[7]   Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography [J].
Comper, WD ;
Jerums, G ;
Osicka, TM .
CLINICAL BIOCHEMISTRY, 2004, 37 (02) :105-111
[8]   High prevalence of immuno-unreactive intact albumin in urine of diabetic patients [J].
Comper, WD ;
Osicka, TM ;
Jerums, G .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2003, 41 (02) :336-342
[9]   Analytical validation of an HPLC assay for urinary albumin [J].
Contois, JH ;
Hartigan, C ;
Rao, LV ;
Snyder, LM ;
Thompson, MJ .
CLINICA CHIMICA ACTA, 2006, 367 (1-2) :150-155
[10]  
GIAMPIETRO O, 1993, CLIN CHEM, V39, P533