Comparison of Multifrequency Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry Assessments in Outpatient Hemodialysis Patients

被引:146
作者
Fuerstenberg, Antje [2 ]
Davenport, Andrew [1 ]
机构
[1] UCL, Sch Med, Ctr Nephrol, London NW3 2PF, England
[2] Royal Free Hosp, Ctr Nephrol, London NW3 2QG, England
关键词
Dual-energy x-ray absorptiometry (DEXA); multifrequency bioimpedance; hemodialysis; nutrition; fat; muscle; BODY-COMPOSITION ASSESSMENT; NUTRITIONAL-STATUS; FLUID STATUS; FAT;
D O I
10.1053/j.ajkd.2010.05.022
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Malnutrition is common in hemodialysis patients and closely related to increased morbidity and mortality. As such, simple, reliable, and easily available methods of determining nutritional status and recognition of short-term changes in body composition are desirable for routine clinical practice. Study Design: Diagnostic test study. Setting & Participants: 53 stable adult hemodialysis patients attending for thrice-weekly outpatient hemodialysis in a university tertiary hospital dialysis center. Index Test: Comparison of dual-energy x-ray absorptiometry (DEXA) and multifrequency bioelectrical impedance analysis (BIA) using a tetrapolar 8-point tactile electrode system as 2 index tests of body composition. Reference Test: None. Results: Assessment of whole-body composition showed that lean body mass measured using the 2 techniques correlated highly, with good method agreement shown using a Bland-Altman plot (r = 0.92; P < 0.001; bias, +1 g [95% CI, -1,173 to 1,175]), as did fat mass (r = 0.93; P < 0.001; bias, -157 g [95% CI, -1,251 to 937]). Similarly, segmental analysis of lean body mass showed strong correlations between lean body mass of the trunk and right and left legs with small bias (r = 0.85, 0.89, and 0.86, respectively; P < 0.001; Bland-Altman bias, -859, +364, and +552 g, respectively), but weaker correlations for lean body mass for the right and left arm (r = 0.69 and 0.75, respectively; P < 0.001; Bland-Altman bias, -240 and +12 g, respectively). Bone mineral content derived using multifrequency BIA overestimated that measured using DEXA (r = 0.77; P < 0.001; bias, +530 g [95% CI, 422-638]). Limitations: Retrospective study in a healthy ambulant outpatient cohort. Conclusions: Compared with DEXA, multifrequency BIA appears to be a robust tool for measuring and monitoring total-body fat and lean body mass in hemodialysis patients; however, there is less agreement in bone mineral content assessment between the 2 methods. Am J Kidney Dis. 57(1): 123-129. (C) 2010 by the National Kidney Foundation, Inc.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 26 条
[1]   Bone mineral density in haemodialysis patients: A comparative study of dual-energy X-ray absorptiometry and quantitative ultrasound [J].
Arici, M ;
Erturk, H ;
Altun, B ;
Usalan, C ;
Ulusoy, S ;
Erdem, Y ;
Sivri, A ;
Yasavul, U ;
Turgan, C ;
Caglar, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (11) :1847-1851
[2]   Assessment of body composition by dual energy X-ray absorptiometry, skinfold thickness and creatinine kinetics in chronic kidney disease patients [J].
Avesani, CM ;
Draibe, SA ;
Kamimura, MA ;
Cendoroglo, M ;
Pedrosa, A ;
Castro, ML ;
Cuppari, L .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (09) :2289-2295
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   N-terminal proBNP-Marker of Cardiac Dysfunction, Fluid Overload, or Malnutrition in Hemodialysis Patients? [J].
Booth, John ;
Pinney, Jennifer ;
Davenport, Andrew .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (06) :1036-1040
[5]  
CHAN TM, 1992, NEPHROL DIAL TRANSPL, V7, P835
[6]  
CHERTOW GM, 1995, J AM SOC NEPHROL, V6, P75
[7]   Vintage, nutritional status, and survival in hemodialysis patients [J].
Chertow, GM ;
Johansen, KL ;
Lew, N ;
Lazarus, JM ;
Lowrie, EG .
KIDNEY INTERNATIONAL, 2000, 57 (03) :1176-1181
[8]   Anthropometric and body composition assessment in dialysis patients [J].
Chumlea, WC .
SEMINARS IN DIALYSIS, 2004, 17 (06) :466-470
[9]   Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance [J].
Davenport, Andrew ;
Willicombe, Michelle .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (11) :779-786
[10]   Hydration Status Does Not Influence Peritoneal Equilibration Test Ultrafiltration Volumes [J].
Davenport, Andrew ;
Willicombe, Michelle Kay .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (07) :1207-1212