Orientational aspects of antibody immobilization and immunological activity on quartz crystal microbalance electrodes

被引:126
作者
Caruso, F [1 ]
Rodda, E [1 ]
Furlong, DN [1 ]
机构
[1] CSIRO,DIV CHEM & POLYMERS,CLAYTON,VIC 3169,AUSTRALIA
关键词
quartz crystal microbalance; antibody; IgG; atomic force microscopy; aggregation;
D O I
10.1006/jcis.1996.0098
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The resonant frequency shift of a quartz crystal microbalance (QCM) has been used to monitor the immobilization of immunoglobulin G (IgG) and anti-IgG antibodies onto unmodified and modified gold QCM electrodes, IgG and anti-IgG antibodies have been immobilized onto, the gold QCM surfaces by four separate methods. First, the antibodies were immobilized directly onto unmodified gold QCM surfaces by physical adsorption. Second, 12-mercaptododecan-1-ol was reacted with the gold surface, and after reaction with bromoacetic acid, the antibodies were coupled to the thiolated surface using a water soluble carbodiimide hydrochloride and N-hydroxysuccinimide. Third, the antibodies were modified by the direct attachment of thiol groups using 2-iminothiolane and subsequently immobilized onto the Bold surface. Fourth, the gold QCM surface was modified by the direct adsorption of Protein A, followed by antibody adsorption. Physical adsorption of the antibodies onto gold QCM electrodes resulted in 30% more bound antibody compared with the covalent attachment and Protein A immobilization methods, Atomic force microscopy( AFM) images of adsorbed IgG onto gold-coated mica revealed the antibodies to be aggregated and randomly distributed on the surface, Tile immobilized receptor layers, prepared by the above four procedures, were allowed to interact with their biospecific partner species, The resulting QCM frequency shifts were used to evaluate both the orientational aspects of antibody immobilization and immunological activities of the immobilized layers. Receptor layers formed by the immobilization of antibodies onto thiolated QCM electrodes did not increase the amount of antibody subsequently bound compared with receptor layers prepared by direct physical adsorption of antibodies, Receptor layers of thiolated antibodies yielded varied immunological activities, The protein A coupling layer between the antibody receptor layer and gold QCM surface facilitated subsequent antibody binding, (C) 1996 Academic Press, Inc.
引用
收藏
页码:104 / 115
页数:12
相关论文
共 58 条
[1]   QUARTZ-CRYSTAL MICROBALANCE STUDY OF THE ADSORPTION OF IONS ONTO GOLD FROM NONAQUEOUS SOLVENTS [J].
ABBOTT, AP ;
LOVEDAY, DC ;
HILLMAN, AR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (11) :1533-1535
[2]   3-DIMENSIONAL STRUCTURE OF AN ANTIGEN-ANTIBODY COMPLEX AT 2.8-A RESOLUTION [J].
AMIT, AG ;
MARIUZZA, RA ;
PHILLIPS, SEV ;
POLJAK, RJ .
SCIENCE, 1986, 233 (4765) :747-753
[3]   EFFECT OF PH ON THE ADSORPTION OF IMMUNOGLOBULIN-G ON ANIONIC POLY(VINYLTOLUENE) MODEL LATEX-PARTICLES [J].
BAGCHI, P ;
BIRNBAUM, SM .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1981, 83 (02) :460-478
[4]   FORMATION OF MONOLAYERS BY THE COADSORPTION OF THIOLS ON GOLD - VARIATION IN THE HEAD GROUP, TAIL GROUP, AND SOLVENT [J].
BAIN, CD ;
EVALL, J ;
WHITESIDES, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (18) :7155-7164
[5]   USE OF MICROWELL PLATES CARRYING HYDRAZIDE GROUPS TO ENHANCE ANTIBODY IMMOBILIZATION IN ENZYME IMMUNOASSAYS [J].
BRILLHART, KL ;
NGO, TT .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 144 (01) :19-25
[6]   EXPERIMENTAL ASPECTS OF USE OF THE QUARTZ CRYSTAL MICROBALANCE IN SOLUTION [J].
BRUCKENSTEIN, S ;
SHAY, M .
ELECTROCHIMICA ACTA, 1985, 30 (10) :1295-1300
[7]   OBSERVATION OF KINETIC EFFECTS DURING INTERFACIAL TRANSFER AT REDOX POLYMER-FILMS USING THE QUARTZ CRYSTAL MICROBALANCE [J].
BRUCKENSTEIN, S ;
WILDE, CP ;
SHAY, M ;
HILLMAN, AR ;
LOVEDAY, DC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 258 (02) :457-462
[8]   AFM STUDIES OF PROTEIN ADSORPTION .1. TIME-RESOLVED PROTEIN ADSORPTION TO HIGHLY ORIENTED PYROLYTIC-GRAPHITE [J].
CULLEN, DC ;
LOWE, CR .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1994, 166 (01) :102-108
[9]   USE OF SCANNING PROBE MICROSCOPY AND SURFACE-PLASMON RESONANCE AS ANALYTICAL TOOLS IN THE STUDY OF ANTIBODY-COATED MICROTITER WELLS [J].
DAVIES, J ;
ROBERTS, CJ ;
DAWKES, AC ;
SEFTON, J ;
EDWARDS, JC ;
GLASBEY, TO ;
HAYMES, AG ;
DAVIES, MC ;
JACKSON, DE ;
LOMAS, M ;
SHAKESHEFF, KM ;
TENDLER, SJB ;
WILKINS, MJ ;
WILLIAMS, PM .
LANGMUIR, 1994, 10 (08) :2654-2661
[10]   FLUORESCENT AND PHOSPHORESCENT STUDY OF LANGMUIR-BLODGETT ANTIBODY FILMS FOR APPLICATION TO IMMUNOSENSORS [J].
DUBROVSKY, TB ;
DEMCHEVA, MV ;
SAVITSKY, AP ;
MANTROVA, EY ;
YAROPOLOV, AI ;
SAVRANSKY, VV ;
BELOVOLOVA, LV .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :377-385