Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system

被引:26
作者
Asadoulahi, Taherah [1 ]
Dadfarnia, Shayessteh [1 ]
Shabani, Ali Mohammad Haji [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
关键词
thallium determination; immobilized crown ether; flow injection; electrothermal atomic absorption spectrometry; matrix separation; analyte preconcentration;
D O I
10.1590/S0103-50532007000700010
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and sensitive flow injection system was developed for separation, preconcentration and determination of thallium. Preconcentration is based on the analyte sorption on a microcolumn of dibenzo-18-crown-6(DB18C6) immobilized on surfactant coated alumina with subsequent elution using a nitric acid solution (500 mu L, 2 mol L-1). The concentration of thallium in the eluent was determined using electrothermal atomic absorption spectrometry. Factors influencing the sorption and desorption of thallium ion were investigated. Using a sample volume of 5 mL, the calibration was linear from 0.1 to 20 mu g L-1 range (r = 0.9996) with a detection limit of 0.05 mu g L-1. The maximum sorption capacity was 1432 mu g of thallium per gram of sorbent. The precision of the method at 1 mu g L-1 was 5.7% RSD (n = 11). The method was applied for determination of thallium in water, hair, nail, and standard reference samples. The accuracy was assessed using addition-recovery experiment or by comparison of the results with certified reference materials.
引用
收藏
页码:1353 / 1359
页数:7
相关论文
共 42 条
[1]  
ABOVMESALAM MM, 2003, J RADIOANAL NUCL CHE, V258, P619
[2]   Immobilization of lithium-selective 14-crown-4 on crosslinked polymer supports [J].
Alexandratos, SD ;
Stine, CL ;
Sachleben, RA ;
Moyer, BA .
POLYMER, 2005, 46 (17) :6347-6352
[3]   Determination of thallium in soils by flame atomic absorption spectrometry [J].
Asami, T ;
Mizui, C ;
Shimada, T ;
Kubota, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (05) :348-351
[4]   Evaluation of Pb-Spec® for flow-injection solid-phase extraction preconcentration for the determination of trace lead in water and wine by flame atomic absorption spectrometry [J].
Bakircioglu, Y ;
Segade, SR ;
Yourd, ER ;
Tyson, JF .
ANALYTICA CHIMICA ACTA, 2003, 485 (01) :9-18
[5]  
Cheam V, 1996, FRESEN J ANAL CHEM, V355, P332
[6]  
Cundeva K, 2001, J SERB CHEM SOC, V66, P709
[7]   Determination of thallium in wine by electrothermal atomic absorption spectrometry after extraction preconcentration [J].
Cvetkovic, J ;
Arpadjan, S ;
Karadjova, I ;
Stafilov, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (06) :1101-1106
[8]   Survey of bottled drinking waters sold in Canada for chlorate, bromide, bromate, lead, cadmium and other trace elements [J].
Dabeka, RW ;
Conacher, HBS ;
Lawrence, JF ;
Newsome, WH ;
McKenzie, A ;
Wagner, HP ;
Chadha, RKH ;
Pepper, K .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (08) :721-732
[9]   Immobilized salen (N,N′-bis (salicylidene) ethylenediamine) as a complexing agent for on-line sorbent extraction/preconcentration and flow injection-flame atomic absorption spectrometry [J].
Dadfarnia, S ;
Shabani, AMH ;
Tamaddon, F ;
Rezaei, M .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :69-75
[10]  
Dadfarnia S, 2002, B KOREAN CHEM SOC, V23, P545