A magnetizing system for dichroism measurements in soft x-ray emission excited by synchrotron radiation

被引:4
作者
Dallera, C [1 ]
Ghiringhelli, G [1 ]
Braicovich, L [1 ]
机构
[1] POLITECN MILAN,DIPARTIMENTO FIS,I-20133 MILAN,ITALY
关键词
D O I
10.1063/1.1146594
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the design and performance of a magnetic circuit suitable for magnetizing solid samples in the measurements of soft x-ray emission dichroism excited by synchrotron radiation. The system allows a variety of samples to be magnetized and satisfies the rather stringent geometrical constraints due to the need for minimizing the effect of photon self-absorption by the sample. The magnetic circuit is ultrahigh vacuum compatible, can reach about 2800 G, and allows fine adjustment of sample position. (C) 1996 American Institute of Physics.
引用
收藏
页码:355 / 357
页数:3
相关论文
共 12 条
[1]  
Braicovich L., UNPUB
[2]   HIGH-EFFICIENCY SOFT-X-RAY EMISSION SPECTROMETER FOR USE WITH SYNCHROTRON RADIATION EXCITATION [J].
CALLCOTT, TA ;
TSANG, KL ;
ZHANG, CH ;
EDERER, DL ;
ARAKAWA, ET .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (11) :2680-2690
[3]   MAGNETIC DICHROISM IN L(2,3) EMISSION OF FE, CO, AND NI FOLLOWING ENERGY-DEPENDENT EXCITATION WITH CIRCULARLY-POLARIZED X-RAYS [J].
DUDA, LC ;
STOHR, J ;
MANCINI, DC ;
NILSSON, A ;
WASSDAHL, N ;
NORDGREN, J ;
SAMANT, MG .
PHYSICAL REVIEW B, 1994, 50 (22) :16758-16761
[4]   HELIOS - A NEW-TYPE OF LINEAR HELICAL UNDULATOR [J].
ELLEAUME, P .
JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 :19-26
[5]   A FLEXIBLE PLANAR HELICAL UNDULATOR DESIGN FOR SYNCHROTRON SOURCES [J].
ELLEAUME, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :371-377
[6]   END STATION FOR POLARIZATION AND EXCITATION-ENERGY SELECTIVE SOFT-X-RAY FLUORESCENCE SPECTROSCOPY [J].
GUO, JH ;
WASSDAHL, N ;
SKYTT, P ;
BUTORIN, SM ;
DUDA, LC ;
ENGLUND, CJ ;
NORDGREN, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1561-1563
[7]   OBSERVATION OF MAGNETIC CIRCULAR-DICHROISM IN FE L2,3 X-RAY-FLUORESCENCE SPECTRA [J].
HAGUE, CF ;
MARIOT, JM ;
STRANGE, P ;
DURHAM, PJ ;
GYORFFY, BL .
PHYSICAL REVIEW B, 1993, 48 (05) :3560-3562
[8]   COSTER-KRONIG CONTRIBUTIONS TO MAGNETIC CIRCULAR-DICHROISM IN THE L(2,3) X-RAY-FLUORESCENCE OF IRON [J].
HAGUE, CF ;
MARIOT, JM ;
GUO, GY ;
HRICOVINI, K ;
KRILL, G .
PHYSICAL REVIEW B, 1995, 51 (02) :1370-1373
[9]   DESIGN OF A PORTABLE LARGE SPECTRAL RANGE GRAZING-INCIDENCE INSTRUMENT [J].
NORDGREN, J ;
NYHOLM, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :242-245
[10]   SOFT-X-RAY EMISSION-SPECTROSCOPY USING MONOCHROMATIZED SYNCHROTRON RADIATION [J].
NORDGREN, J ;
BRAY, G ;
CRAMM, S ;
NYHOLM, R ;
RUBENSSON, JE ;
WASSDAHL, N .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1690-1696