A design for improved neutron collimators

被引:19
作者
Cussen, LD [1 ]
机构
[1] Victoria Univ Technol, Sch Commun & Informat, Melbourne, Vic 8001, Australia
关键词
neutron scattering; collimators; instrumentation;
D O I
10.1016/S0168-9002(98)00664-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Seller slit collimators are widely used to define beams of thermal neutrons for scattering experiments and hence to tailor the instrumental resolution. The possibility of using neutron guide principles to increase the overall transmission of a collimator for a given overall instrumental resolution has long been recognised. Advances over the last decades in the semiconductor industry now provide the technology to make such collimators. A feasible design is to use blades of flat silicon wafers on which non-polarising neutron supermirrors are vacuum deposited. In its simplest form the coating would consist of two thin layers of a material with a large scattering length, such as nickel, sandwiching a neutron absorbing layer such as gadolinium. Calculations show that such devices could increase the counting rate at the detector by up to 47% per collimator for a given instrumental resolution. A simpler design where the silicon wafers support a thin absorbing layer alone is also described and can be used to build very short, high transmission conventional neutron collimators. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:365 / 371
页数:7
相关论文
共 18 条
[1]   HIGH-EFFICIENCY SOLLER SLIT COLLIMATORS FOR 1-EV NEUTRONS [J].
CARLILE, CJ ;
PENFOLD, J ;
WILLIAMS, WG .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (08) :837-838
[2]   HIGH-EFFICIENCY SOLLER SLIT COLLIMATORS FOR THERMAL-NEUTRONS [J].
CARLILE, CJ ;
HEY, PD ;
MACK, B .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1977, 10 (05) :543-546
[3]   POLARIZING TI(1-U)X(U)/FEXCOYVZ SUPERMIRRORS [J].
CLEMENS, D ;
BONI, P ;
FRIEDLI, HP ;
GOTTEL, R ;
FERMON, C ;
GRIMMER, H ;
VANSWYGENHOVEN, H ;
ARCHER, J ;
KLOSE, F ;
KRIST, T ;
MEZEI, F ;
THOMAS, P .
PHYSICA B, 1995, 213 :942-944
[4]  
CUSSEN LD, 1998, IN PRESS NUCL INST A
[5]   NEUTRON TRANSMISSION PROPERTIES OF PERFECT SILICON-CRYSTALS [J].
FREUND, AK ;
FRIEDRICH, H ;
NISTLER, W ;
SCHERM, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (01) :116-121
[6]  
GOLOSOVSKY IV, 1984, NUCL INSTRUM METH A, V234, P418
[7]  
Golub R., 1991, ULTRA COLD NEUTRONS
[8]   NEUTRON DIFFRACTION STUDIES OF ZINC FERRITE AND NICKEL FERRITE [J].
HASTINGS, JM ;
CORLISS, LM .
REVIEWS OF MODERN PHYSICS, 1953, 25 (01) :114-121
[9]   COMPACT POLARIZING SOLLER GUIDES FOR COLD NEUTRONS [J].
HAYTER, JB ;
PENFOLD, J ;
WILLIAMS, WG .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (05) :454-458
[10]   D1A, A HIGH-RESOLUTION NEUTRON POWDER DIFFRACTOMETER WITH A BANK OF MYLAR COLLIMATORS [J].
HEWAT, AW ;
BAILEY, I .
NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (03) :463-471