Collaborative study of a T-nos real-time PCR method for screening of genetically modified organisms in food products

被引:38
作者
Reiting, R. [4 ]
Broll, H. [3 ]
Wablinger, H. -U. [2 ]
Grohmann, L. [1 ]
机构
[1] Bundesamt Verbraucherschutz & Lebensmittelsicherh, D-10117 Berlin, Germany
[2] Chem & Veterinaruntersuchgsamt Freiburg, Freiburg, Germany
[3] Bundesinst Risikobewertung, Berlin, Germany
[4] Landesbetrieb Hess Landeslabor, Kassel, Germany
来源
JOURNAL FUR VERBRAUCHERSCHUTZ UND LEBENSMITTELSICHERHEIT-JOURNAL OF CONSUMER PROTECTION AND FOOD SAFETY | 2007年 / 2卷 / 02期
关键词
genetically modified organisms (GMO); screening; nos terminator (T-nos); real-time PCR; collaborative study;
D O I
10.1007/s00003-007-0189-4
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In the EU the presence of genetically modified organisms (GMO) in food is controlled by the Member States official laboratories within their national inspection and monitoring programs. The most frequently used approach to detect the presence of GMO material in different food matrices is the PCR-based screening for the CaMV 35S promoter and the nos terminator (T-nos) DNA sequence from Agrobacterium tumefaciens. A real-time PCR method for detection of T-nos and its validation in a collaborative trial study is described in this paper. The PCR system amplifies a 84 bp fragment and showed to be sensitive to detect at least 5 copies of the T-nos DNA sequence. The assay was adapted for use in real-time PCR instruments using plastic reaction vials and glass capillaries, respectively. A total of 24 laboratories participated in the study and each laboratory received 18 DNA blind samples prepared from GMO certified reference materials (0.1 % and 0.5 % NK601 maize) and from a non-GM maize flour. All samples containing NK603 maize DNA were correctly classified as T-nos positive by the participating laboratories. For the blank samples (0 % GMO) only three false-positive results were reported. A detailed evaluation of the results of the collaborative trial study is described.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 21570 ISO
[2]  
[Anonymous], 2005, 21569 ISO
[3]  
Arumuganathan K, 1991, PLANT MOL BIOL REP, V9, P208, DOI [10.1007/BF02672069, DOI 10.1007/BF02672069]
[4]  
*COMM REF LAB, VAL DET METH COMM RE
[5]  
*ENGL, 2005, DEF MIN PERF REQ AN
[6]   Real-time multiplex PCR:: An accurate method for the detection and quantification of 35S-CaMV promoter in genetically modified maize-containing food [J].
Höhne, M ;
Santisi, CR ;
Meyer, R .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2002, 215 (01) :59-64
[7]  
HOLLAND PM, 1991, P NATL ACAD SCI USA, V88, P357
[8]  
Holst-Jensen A, 2004, J AOAC INT, V87, P927
[9]   PROTOCOL FOR THE DESIGN, CONDUCT AND INTERPRETATION OF METHOD-PERFORMANCE STUDIES [J].
HORWITZ, W .
PURE AND APPLIED CHEMISTRY, 1995, 67 (02) :331-343
[10]  
ISO, 2005, ISO Standard No. 21571)