Assessment of flow velocity reserve by transthoracic Doppler echocardiography and venous adenosine infusion before and after left anterior descending coronary artery stenting

被引:85
作者
Pizzuto, F [1 ]
Voci, P [1 ]
Mariano, E [1 ]
Puddu, PE [1 ]
Sardella, G [1 ]
Nigri, A [1 ]
机构
[1] Univ Roma La Sapienza, Inst Cardiac Surg, Sect Cardiol 2, Rome, Italy
关键词
D O I
10.1016/S0735-1097(01)01333-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective We sought to evaluate whether coronary flow velocity reserve (CFR) (the ratio between hyperemic and baseline peak flow velocity), as measured by transthoracic Doppler echocardiography during adenosine infusion, allows detection of flow changes in the left anterior descending coronary artery (LAD) before and after stenting. Background The immediate post-stenting evaluation of CFR by intracoronary Doppler has shown mixed results, due to reactive hyperemia and microvascular stunning. Noninvasive coronary Doppler echocardiography may be a more reliable measure than intracoronary Doppler. Methods Transthoracic Doppler echocardiography during 90-s venous adenosine infusion (140 mug/kg body weight per min) was used to measure CFR of the LAD in 45 patients before and 3.7 +/- 2 days after successful stenting, as well as in 25 subjects with an angiographically normal LAD (control group). Results Adequate Doppler spectra were obtained in 96% of the patients. Pre-stent CFR was significantly lower in patients than in control subjects (diastolic CFR: 1.45 +/- 0.5 vs. 2.72 +/- 0.71, p < 0.01; systolic CFR: 1.61 <plus/minus> 1.02 vs. 2.41 +/- 0.68, p < 0.01) and increased toward the normal range after stenting (diastolic CFR: 2.58 <plus/minus> 0.7 vs. 2.72 +/- 0.75, p = NS; systolic CFR: 2.43 +/- 1.01 vs. 2.41 +/- 0.52, p = NS). Diastolic CFR was often damped, suggesting coronary steal in patients with greater than or equal to 90% versus <90% LAD stenosis (0.86 <plus/minus> 0.23 vs. 1.69 +/- 0.43, p < 0.01). Coronary stenting normalized diastolic CFR in these two groups (2.45 <plus/minus> 0.77 and 2.64 +/- 0.69, respectively, p = NS), even though impaired diastolic CFR persisted in three of four patients with greater than or equal to 90% stenosis. Stenosis of the LAD was better discriminated by diastolic (F = 49.30) than systolic (F = 12.20) CFR (both p < 0.01). Conclusions Coronary flow reserve, as measured by transthoracic Doppler echocardiography, is impaired in LAD disease; it may identify patients with <greater than or equal to>90% stenosis; and it normalizes early after stenting, even in patients with greater than or equal to 90% stenosis. (J Am Coll Cardiol 2001;38:155-62) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 33 条
[1]   TOLERANCE AND SAFETY OF PHARMACOLOGICAL CORONARY VASODILATION WITH ADENOSINE IN ASSOCIATION WITH TL-201 SCINTIGRAPHY IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE [J].
ABREU, A ;
MAHMARIAN, JJ ;
NISHIMURA, S ;
BOYCE, TM ;
VERANI, MS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :730-735
[2]   Coronary artery flow velocity is related to lumen area and regional left ventricular mass [J].
Anderson, HV ;
Stokes, MJ ;
Leon, M ;
Abu-Halawa, SA ;
Stuart, Y ;
Kirkeeide, RL .
CIRCULATION, 2000, 102 (01) :48-54
[3]   Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine - A noninvasive, rapid and effective method for coronary flow reserve assessment [J].
Caiati, C ;
Zedda, N ;
Montaldo, C ;
Montisci, R ;
Iliceto, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (01) :122-130
[4]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[5]   PHASIC CORONARY BLOOD-FLOW VELOCITY IN INTRAMURAL AND EPICARDIAL CORONARY-ARTERIES [J].
CHILIAN, WM ;
MARCUS, ML .
CIRCULATION RESEARCH, 1982, 50 (06) :775-781
[6]   CORONARY-ARTERY VASOCONSTRICTION ROUTINELY OCCURS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - A QUANTITATIVE ARTERIOGRAPHIC ANALYSIS [J].
FISCHELL, TA ;
DERBY, G ;
TSE, TM ;
STADIUS, ML .
CIRCULATION, 1988, 78 (06) :1323-1334
[7]   ENDOTHELIUM-DEPENDENT ARTERIAL VASOCONSTRICTION AFTER BALLOON ANGIOPLASTY [J].
FISCHELL, TA ;
NELLESSEN, U ;
JOHNSON, DE ;
GINSBURG, R .
CIRCULATION, 1989, 79 (04) :899-910
[8]   LOCAL EFFECT OF SEROTONIN RELEASED DURING CORONARY ANGIOPLASTY [J].
GOLINO, P ;
PISCIONE, F ;
BENEDICT, CR ;
ANDERSON, HV ;
CAPPELLIBIGAZZI, M ;
INDOLFI, C ;
CONDORELLI, M ;
CHIARIELLO, M ;
WILLERSON, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 330 (08) :523-528
[9]   NONINVASIVE ASSESSMENT OF CORONARY STENOSES BY MYOCARDIAL PERFUSION IMAGING DURING PHARMACOLOGICAL CORONARY VASODILATION .8. CLINICAL FEASIBILITY OF POSITRON CARDIAC IMAGING WITHOUT A CYCLOTRON USING GENERATOR-PRODUCED RB-82 [J].
GOULD, KL ;
GOLDSTEIN, RA ;
MULLANI, NA ;
KIRKEEIDE, RL ;
WONG, WH ;
TEWSON, TJ ;
BERRIDGE, MS ;
BOLOMEY, LA ;
HARTZ, RK ;
SMALLING, RW ;
FUENTES, F ;
NISHIKAWA, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) :775-789
[10]   EFFECTS OF CORONARY STENOSES ON CORONARY FLOW RESERVE AND RESISTANCE [J].
GOULD, KL ;
LIPSCOMB, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (01) :48-55