Filling hemodialysis catheters in the interdialytic period: Heparin versus citrate versus polygeline: A prospective randomized study

被引:70
作者
Buturovic, J
Ponikvar, R
Kandus, A
Boh, M
Klinkmann, J
Ivanovich, P
机构
[1] Univ Ljubljana, Med Ctr, Dept Nephrol, Dialysis Ctr, Ljubljana 1000, Slovenia
[2] Northwestern Univ, Lakeside Div, VA Chicago Healthcare Syst, Chicago, IL 60611 USA
关键词
hemodialysis; catheters; heparin; heparin lock; citrate; polygeline;
D O I
10.1046/j.1525-1594.1998.06268.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heparin and saline are commonly used to fill hemodialysis central venous catheters to prevent their thrombosis during the interdialytic period. The purpose of this prospective clinical study was to evaluate whether replacing heparin with citrate or polygeline could ensure satisfactory catheter function without exposing patients to the, risk of systemic heparinization. Thirty end-stage renal disease (ESRD) patients with subclavian or jugular single lumen catheters as temporary vascular access for hemodialysis were enrolled. After the insertion of the catheters, the patients were randomly assigned to one of the following three filling groups: Group A, heparin; Group B, citrate; Group C, polygeline. Before each dialysis, the filling solution was aspirated and clot volume, if present, was measured. The catheter usage time and the clot volume were 23 +/- 24 days and 0.052 +/- 0.035 ml in Group A, 51 +/- 36 days and 0.059 +/- 0.032 ml in Group B, and 32 +/- 10 days and 0.056 +/- 0.038 ml in Group C, respectively. Our results indicate that citrate or polygeline can replace heparin effectively as a filling solution for single lumen temporary hemodialysis catheters.
引用
收藏
页码:945 / 947
页数:3
相关论文
共 9 条
[1]  
BERKOBEN MS, 1995, CLIN DIALYSIS, P26
[2]   CONTROL OF ORAL ANTICOAGULATION IN PATIENTS USING LONG-TERM INTERNAL JUGULAR CATHETERS FOR HEMODIALYSIS ACCESS [J].
BESLEY, M ;
THOMAS, A ;
SALTER, S ;
SANG, YY ;
VAS, M ;
ULDALL, PR .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (05) :277-280
[3]  
NKF-DOQI, 1997, AM J KIDNEY DIS S3, V30, pS150
[4]  
PONIKVAR R, 1997, ARTIF ORGANS, V21, P562
[5]  
PONIKVAR R, 1995, ARTIF ORGANS, V19, pA1039
[6]  
PONIKVAR R, 1994, INT J ARTIF ORGANS, V17, P421
[7]  
TOULON J, 1994, NEPHROLOGIE, V15, P95
[8]   Use of double-lumen dialysis catheters - Loading with locked heparin [J].
Trivedi, HS ;
Twardowski, ZJ .
ASAIO JOURNAL, 1997, 43 (06) :900-903
[9]  
Uldall Robert, 1996, P277, DOI 10.1007/978-0-585-36947-1_10