Magnetic resonance imaging for in vivo assessment of three-dimensional patellar tracking

被引:56
作者
Fellows, RA
Hill, NA
Gill, HS
MacIntyre, NJ
Harrison, MM
Ellis, RE
Wilson, DR
机构
[1] Univ British Columbia, Dept Orthopaed, Vancouver Hosp, Vancouver, BC V5Z 4E3, Canada
[2] Univ British Columbia, Hlth Sci Ctr, Vancouver, BC V5Z 4E3, Canada
[3] Queens Univ, Dept Phys Therapy, Kingston, ON, Canada
[4] Queens Univ, Human Mobil Res Ctr, Kingston, ON, Canada
[5] Queens Univ, Sch Comp, Kingston, ON, Canada
[6] Queens Univ, Dept Surg, Kingston, ON, Canada
[7] Queens Univ, Dept Mech Engn, Kingston, ON, Canada
[8] Univ Oxford, Nuffield Dept Orthopaed Surg, OOCE, Nuffield Orthopaed Ctr, Oxford, England
基金
加拿大健康研究院;
关键词
knee; patella; kinematics; MRI; biomechanics; accuracy; tracking; patellofemoral joint;
D O I
10.1016/j.jbiomech.2004.07.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
We have developed a non-invasive measurement technique which can ultimately be used to quantify three-dimensional patellar kinematics of human subjects for a range of static positions of loaded flexion and assessed its accuracy. Knee models obtained by segmenting and reconstructing one high-resolution scan of the knee were registered to bone outlines obtained by segmenting fast, low-resolution scans of the knee in static loaded flexion. We compared patellar tracking measurements made using the new method to measurements made using Roentgen stereophotogrammetric analysis in three cadaver knee specimens loaded through a range of flexion in a test rig. The error in patellar spin and tilt measurements was less than 1.02 degrees and the error in lateral patellar shift was 0.88 mm. Sagittal plane scans provided more accurate final measurements of patellar spin and tilt, whereas axial plane scans provided more accurate measurements of lateral translation and patellar flexion. Halving the number of slices did not increase measurement error significantly, which suggests that scan times can be reduced without reducing accuracy significantly. The method is particularly useful for multiple measurements on the same subject because the high-resolution bone-models need only be created once; thus, the potential variability in coordinate axes assignment and model segmentation during subsequent measurements is removed. (c) 2004 Published by Elsevier Ltd.
引用
收藏
页码:1643 / 1652
页数:10
相关论文
共 24 条
[1]
In vitro measurement of the tracking pattern of the human patella [J].
Ahmed, AM ;
Duncan, NA ;
Tanzer, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02) :222-228
[2]
Cement migration after THR -: A comparison of Charnley Elite and Exeter femoral stems using RSA [J].
Alfaro-Adrián, J ;
Gill, HS ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :130-134
[3]
[Anonymous], DISORDERS PATELLOFEM
[4]
A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]
Crisco TJ, 1999, J ORTHOP RES, V17, P96
[6]
CROITORU H, 2001, COMPUTER AIDED SURG, V6, P106
[7]
Ellis R E, 1999, Comput Aided Surg, V4, P264
[8]
FELLOWS RA, 2004, 50 M ORTH RES SOC
[9]
THE EPIDEMIOLOGY OF KNEE OSTEOARTHRITIS - RESULTS FROM THE FRAMINGHAM OSTEOARTHRITIS STUDY [J].
FELSON, DT .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1990, 20 (03) :42-50
[10]
GROOD ES, 1994, BIOMECH ENG, V105, P136