Two-dimensional LC-MS analysis of components in Swertia franchetiana Smith

被引:17
作者
Liu, Yanming [1 ]
Xu, Qing [1 ]
Xue, Xingya [1 ]
Zhang, Feifang [1 ]
Liang, Xinmiao [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Grad Sch, Dalian 116023, Peoples R China
关键词
mass spectrometry; on-column focusing; Swertia franchetiana Smith; traditional Chinese medicine; two-dimensional liquid chromatography;
D O I
10.1002/jssc.200700393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An off-line 2-D-LC approach was developed for the separation and identification of components in extracts of Swertia franchetiana Smith, which is a traditional Chinese medicine. An octadecylsilica column was used for further separation of fractions from a cyano column with UV and MS detection. In this method, a longer column was used in the second dimension to improve the separation ability, and "on-column focusing" was adopted to reduce sample loss and pollution on concentrating the fractions from the first dimension. More than 118 and 575 components were detected in the chloroform and n-butanol extracts by this method, respectively. In contrast, only 20 and 95 peaks were detected by the one-dimensional method. Most of the additionally detected compounds were of low-abundance components. Many compounds can be preliminarily identified according to their UV and mass spectra in the two-dimensional method. The obtained results not only demonstrated the powerful resolution of 2-D-LC, but also led to in-depth comprehension of the UV and mass spectra of complex samples.
引用
收藏
页码:935 / 944
页数:10
相关论文
共 32 条
[1]   Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils of differing complexities [J].
Bicchi, C ;
Brunelli, C ;
Cordero, C ;
Rubiolo, P ;
Galli, M ;
Sironi, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) :195-207
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[3]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[4]   Development of different comprehensive two dimensional systems for the separation of phenolic antioxidants [J].
Cacciola, Francesco ;
Jandera, Pavel ;
Blahova, Eva ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (16) :2500-2513
[5]   On-line reversed-phase liquid chromatography-gas chromatography coupled to mass spectrometry for enantiomeric analysis of chiral compounds in fruit beverages [J].
Caja, MM ;
Blanch, GP ;
Herraiz, M ;
del Castillo, MLR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) :81-85
[6]   Chromatofocusing nonporous reversed-phase high-performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of proteins from human breast cancer whole cell lysates: a novel two-dimensional liquid chromatography/mass spectrometry method [J].
Chong, BE ;
Yan, F ;
Lubman, DM ;
Miller, FR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (04) :291-296
[7]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[8]   Off-line coupling of non-aqueous reversed-phase and silver ion high-performance liquid chromatography-mass spectrometry for the characterization of rice oil triacylglycerol positional isomers [J].
Dugo, P ;
Favoino, O ;
Tranchida, PQ ;
Dugo, G ;
Mondello, L .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :135-142
[9]   LOW-COST GRADIENT SYSTEM FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - QUANTITATION OF COMPLEX PHARMACEUTICAL RAW-MATERIALS [J].
ERNI, F ;
FREI, RW ;
LINDNER, W .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (01) :265-274
[10]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569