Percutaneous thoracic and abdominal aortic aneurysm repair: Techniques and outcomes

被引:19
作者
Hogg, Melissa E. [1 ]
Kibbe, Melina R. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Div Vasc Surg, Chicago, IL 60611 USA
关键词
abdominal aortic aneurysm; atherosclerosis; endovascular interventions;
D O I
10.2310/6670.2006.00051
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Endovascular repair of infrarenal abdominal aortic aneurysms (EVAR) has become a widely accepted treatment modality. The conventional approach of an EVAR involves bilateral groin incisions to expose the femoral arteries followed by introducer sheath placement, which is typically performed with the use of general or epidural anesthesia. As technology trends toward less invasive methods and sheath sizes become smaller, the use of a total percutaneous approach to endovascular repair of aortic pathology is becoming more common. In this review, we present a brief history of percutaneous closure devices for common femoral artery access, factors important in patient selection, the technique of performing a percutaneous EVAR procedure, early and late complications, and overall outcomes of percutaneous approaches for the endovascular treatment of aortic pathology.
引用
收藏
页码:270 / 281
页数:12
相关论文
共 37 条
[1]   Endovascular treatment of thoracic aortic disease - Four years of experience [J].
Bortone, AS ;
De Cillis, E ;
D'Agostino, D ;
Schinosa, LDT .
CIRCULATION, 2004, 110 (11) :II262-II267
[2]   Infectious and ischemic complications from percutaneous closure devices used after vascular access [J].
Boston, US ;
Panneton, JM ;
Hofer, JM ;
Sabater, EA ;
Caplice, N ;
Rowland, CM ;
Noel, AA ;
Bower, TC ;
Cherry, KJ ;
Gloviczki, P .
ANNALS OF VASCULAR SURGERY, 2003, 17 (01) :66-71
[3]   Angiographic follow-up after suture-mediated femoral artery closure [J].
Brown, DB ;
Crawford, ST ;
Norton, PL ;
Hovsepian, DM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (07) :677-680
[4]   Suture-mediated percutaneous closure of antegrade femoral arterial access sites in patients who have received full anticoagulation therapy [J].
Duda, SH ;
Wiskirchen, J ;
Erb, M ;
Schott, U ;
Khaligi, K ;
Pereira, PL ;
Albes, J ;
Claussen, CD .
RADIOLOGY, 1999, 210 (01) :47-52
[5]   Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device [J].
Gerckens, U ;
Cattelaens, N ;
Lampe, EG ;
Grube, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (12) :1658-1663
[6]   Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial [J].
Greenhalgh, RM ;
Brown, LC ;
Kwong, GPS ;
Powell, JT ;
Thompson, SG .
LANCET, 2004, 364 (9437) :843-848
[7]  
Haas PC, 1999, J ENDOVASC SURG, V6, P168, DOI 10.1583/1074-6218(1999)006<0168:COLPAS>2.0.CO
[8]  
2
[9]   Percutaneous repair of abdominal aortic aneurysms using the AneuRx stent graft and the percutaneous vascular surgery device [J].
Howell, M ;
Doughtery, K ;
Strickman, N ;
Krajcer, Z .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (03) :281-287
[10]  
Howell M, 2001, J ENDOVASC THER, V8, P68, DOI 10.1583/1545-1550(2001)008<0068:PAACOF>2.0.CO