Scanning small angle X-ray scattering analysis of human bone sections

被引:192
作者
Rinnerthaler, S
Roschger, P
Jakob, HF
Nader, A
Klaushofer, K
Fratzl, P
机构
[1] Hanusch Hosp, Dept Med 4, Ludwig Boltzmann Inst Osteol, A-1140 Vienna, Austria
[2] Univ Vienna, Mat Phys Inst, Vienna, Austria
[3] Hanusch Hosp, Inst Pathol, Vienna, Austria
关键词
SAXS; mineral crystals; calcified tissue; human bone; position resolution;
D O I
10.1007/PL00005824
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Scanning small-angle X-ray scattering (scanning SAXS) was applied for the first time on bone to compare results from SAXS directly with those from other position-sensitive methods, such as light and polarized light microscopy, back-scattered electron imaging, and radiographic imaging. Since scanning SAXS is a nondestructive method of investigation, images from all these techniques could be obtained from the same bone sections. Thus, it could be shown that both the collagen and the mineral crystals were predominantly aligned parallel to the trabeculae and, therefore, to principle stress directions. Moreover, the mean crystal thickness as determined by scanning SAXS was found to be different at various positions inside the trabecular and cortical structure. Finally, it could be shown that scanning SAXS is suitable for detecting local changes in bone material, e.g., due to fluoride treatment.
引用
收藏
页码:422 / 429
页数:8
相关论文
共 42 条
[1]   SKELETAL FLUOROSIS - HISTOMORPHOMETRIC ANALYSIS OF BONE CHANGES AND BONE FLUORIDE CONTENT IN 29 PATIENTS [J].
BOIVIN, G ;
CHAVASSIEUX, P ;
CHAPUY, MC ;
BAUD, CA ;
MEUNIER, PJ .
BONE, 1989, 10 (02) :89-99
[2]   ULTRASOUND AND DENSITOMETRY OF THE CALCANEUS CORRELATE WITH THE FAILURE LOADS OF CADAVERIC FEMURS [J].
BOUXSEIN, ML ;
COURTNEY, AC ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (02) :99-103
[3]  
Boyde A, 1996, MICROSC RES TECHNIQ, V33, P92
[4]  
BOYDE A, 1972, BIOCH PHYSL BONE, V1, P268
[5]   AGING OF BONE TISSUE - MECHANICAL-PROPERTIES [J].
BURSTEIN, AH ;
REILLY, DT ;
MARTENS, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :82-86
[6]   ORIENTATION OF COLLAGEN IN HUMAN TIBIAL AND FIBULAR SHAFT AND POSSIBLE CORRELATION WITH MECHANICAL-PROPERTIES [J].
CARANDO, S ;
BARBOS, MP ;
ASCENZI, A ;
BOYDE, A .
BONE, 1989, 10 (02) :139-142
[7]   Predictive value of proximal femoral bone densitometry in determining local orthogonal material properties [J].
Cody, DD ;
McCubbrey, DA ;
Divine, GW ;
Gross, GJ ;
Goldstein, SA .
JOURNAL OF BIOMECHANICS, 1996, 29 (06) :753-761
[8]   PHYSICAL CHARACTERISTICS AFFECTING THE TENSILE FAILURE PROPERTIES OF COMPACT-BONE [J].
CURREY, JD .
JOURNAL OF BIOMECHANICS, 1990, 23 (08) :837-844
[9]  
DELLING G, 1995, NEPHROL DIAL TRANSPL, V10, P601
[10]  
EANES E. D., 1965, ARCH ORAL BIOL, V10, P161, DOI 10.1016/0003-9969(65)90068-3