Strain shielding in proximal tibia of stemmed knee prosthesis: Experimental study

被引:81
作者
Completo, A. [1 ]
Fonseca, F. [2 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, Dept Engn Mecan, P-3810193 Aveiro, Portugal
[2] Univ Beira Interior, Fac Ciencias Saude, P-6201001 Covilha, Portugal
关键词
revision total knee arthroplasty; stress shielding; tibia; press-fit stem; cemented stem; experimental strains;
D O I
10.1016/j.jbiomech.2007.10.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stems can place abnormal stresses through even normal bone by their constrained design, type of materials and fixation method and may contribute for bone loss. Experimental quantification of strain shielding in the proximal synthetic tibia following TKA is the main purpose of the present study. In this study, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic tibias before and after in vitro knee surgery. Three tibias were implanted with cemented and press-fit stem augments and solely with a tibial tray (short monobloc stem) of the P.F.C. Sigma Modular Knee System. The difference between principal strains of the implanted and the intact tibia was calculated for each strain gauge position. The results demonstrated a pronounced strain-shielding effect in the proximal level, close to tibial tray with the cemented stem augment. The press-fit stem presented a minor effect of strain shielding but was more extensively throughout the stem. An increase of strains closely to the distal tip of the cemented and the press-fit stem augment was observed. This suggests for a physiological condition, a potential effect of bone resorption at the proximal region for the cemented stem augment. The localized increase of strains in stems tip can be related with the clinical finding of the pain, at the end of stem after revision TKA. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:560 / 566
页数:7
相关论文
共 30 条
[1]
The effect of stem design on end-of-stem pain in revision total knee arthroplasty [J].
Barrack, RL ;
Stanley, T ;
Burt, M ;
Hopkins, S .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :119-124
[2]
BARRACK RL, 1999, CLIN ORTHOP RELAT R, V367, P216
[3]
STEMMED REVISION ARTHROPLASTY FOR ASEPTIC LOOSENING OF TOTAL KNEE REPLACEMENT [J].
BERTIN, KC ;
FREEMAN, MAR ;
SAMUELSON, KM ;
RATCLIFFE, SS ;
TODD, RC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :242-248
[4]
Bohr H H, 1987, J Arthroplasty, V2, P309, DOI 10.1016/S0883-5403(87)80064-5
[5]
BOURNE RB, 1986, CLIN ORTHOP RELAT R, P95
[6]
CHRIST RM, 2000, 67 ANN M AM AC ORTH
[7]
Finite element and experimental cortex strains of the intact and implanted tibia [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (05) :791-797
[8]
Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[9]
A TECHNIQUE FOR THE INVITRO MEASUREMENT OF PRINCIPAL STRAINS IN THE HUMAN TIBIA [J].
FINLAY, JB ;
BOURNE, RB ;
MCLEAN, J .
JOURNAL OF BIOMECHANICS, 1982, 15 (10) :723-739
[10]
The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty - The posteromedial hot spot [J].
Green, GV ;
Berend, KR ;
Berend, ME ;
Glisson, RR ;
Vail, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1033-1039