Optimal dose of Gd-DTPA in dynamic MR studies

被引:41
作者
Rusinek, H [1 ]
Lee, VS [1 ]
Johnson, G [1 ]
机构
[1] NYU, Sch Med, Dept Radiol, New York, NY USA
关键词
dose of Gd-DTPA; concentration of Gd-DTPA; dynamic MR imaging; error analysis;
D O I
10.1002/mrm.1193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The relationship between the administered dose d of Gd-DTPA and the accuracy of measurements of the glomerular filtration rate G and the cardiac output O was investigated. For a wide range of values the concentration of Gd-DTPA can be uniquely derived from MR signals and precontrast longitudinal relaxation time. Fixed and random errors in these measured variables were analyzed. Depending on noise level and the level of renal function, errors in G reach a minimum for d = 1.4-2.8 mmol. Random errors in G are relatively insensitive to d as long as d > 1.5 mmol. These results establish the feasibility of dynamic MR measurements using doses of Gd-DTPA that are several times lower than current standards. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:312 / 316
页数:5
相关论文
共 16 条
[1]  
[Anonymous], 1992, ART SCI COMPUTING
[2]   MAGNETIC-RELAXATION IN BLOOD AND BLOOD-CLOTS [J].
BRYANT, RG ;
MARILL, K ;
BLACKMORE, C ;
FRANCIS, C .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :133-144
[3]  
DIFFEY BL, 1976, J NUCL MED, V17, P352
[4]  
FOSTER DM, 1988, COMPUT BIOL MED, V18, P153
[5]   RAPID CALCULATION OF T1 USING VARIABLE FLIP ANGLE GRADIENT REFOCUSED IMAGING [J].
FRAM, EK ;
HERFKENS, RJ ;
JOHNSON, GA ;
GLOVER, GH ;
KARIS, JP ;
SHIMAKAWA, A ;
PERKINS, TG ;
PELC, NJ .
MAGNETIC RESONANCE IMAGING, 1987, 5 (03) :201-208
[7]   Diagnosis of renovascular hypertension: Feasibility of captopril-sensitized dynamic MR imaging and comparison with captopril scintigraphy [J].
Grenier, N ;
Trillaud, H ;
Combe, C ;
Degreze, P ;
Jeandot, R ;
Gosse, P ;
Douws, C ;
Palussiere, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :835-843
[8]   ERROR ANALYSIS BY SIMULATION STUDIES IN RENOGRAPHY DECONVOLUTION [J].
GULLQUIST, RR ;
FLEMING, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03) :383-395
[9]   Studies on the circulation IV. Further analysis of the injection method, and of changes in hemodynamtcs under physiological and pathological conditions [J].
Hamilton, WF ;
Moore, JW ;
Kinsman, JM ;
Spurling, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 99 (03) :534-551
[10]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233