Optical determination of low-level water concentrations in organic solvents using fluorescent acridinyl dyes and dye-immobilized polymer membranes

被引:140
作者
Citterio, D
Minamihashi, K
Kuniyoshi, Y
Hisamoto, H
Sasaki, S
Suzuki, K
机构
[1] Keio Univ, Dept Appl Chem, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] KAST, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
关键词
D O I
10.1021/ac010535q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fluorescent acridinyl indicators 4-(9-acridinyl)-N-(5-hexenyl)-N-methylaniline (KD-F0011), 6-(9-acridinyl)-,2,2,3-tetramethyl-2,3-dihydro-1H-perimidine (KD-F0021 1), and 6-(9-acridinyl)-2-(3-butenyl)-1,2,3-trimethyl-2,3-dihydro-1H-perimidine (KD-F0022) were designed, synthesized, and applied for highly sensitive optical determination of low-level water in organic solvents. All these dyes were found useful as fluorescence indicators for the detection of water below 1% (v/v) in different solvent media with a low detection limit of 0.002% (v/v) or 20 mg/L (22 ppm by weight) for KD-F0021 in THF solution. Sensing membranes made from poly(ethylene glycol) dimethacrylate by photocopolymerization with the indicator KD-F0011 were also prepared. Using the membrane sensor, the lowest detection limit of 0.001% (v/v) or 14 mg/L (20 ppm) water was achieved in diethyl ether samples. This system enables the continuous monitoring of the water content in a flow-through arrangement, where single-wavelength excitation (404 nm) and single-wavelength detection (532 nm) can be used for the fluorescence determination, allowing a simple measurement setup. In a continuous-flow experiment using THF samples, fully reversible and fast signal changes with t(95%) = 1-2 min for water concentrations up to 0.50% (v/v) were observed. A detection limit of 0.004% (v/v) or 40 mg/L (45 ppm) water in THF was achieved. These characteristics make this type of sensor a useful tool for the online continuous monitoring of water present as an impurity in organic media, which is difficult to achieve using a Karl Fischer instrument.
引用
收藏
页码:5339 / 5345
页数:7
相关论文
共 21 条
[1]  
ARTER JC, 1999, PITTCON 99 PITTSB C, P1143
[2]   A FIBER OPTIC SENSOR FOR WATER IN ORGANIC-SOLVENTS BASED ON POLYMER SWELLING [J].
BAI, MQ ;
SEITZ, WR .
TALANTA, 1994, 41 (06) :993-999
[3]   CHARACTERIZATION OF SURGICAL ADHESIVES FROM UV-POLYMERIZED POLY(PEG DIMETHACRYLATE-CO-2-HYDROXYETHYL METHACRYLATE) COPOLYMERS [J].
BERKOWICZ, BD ;
PEPPAS, NA .
JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 56 (06) :715-720
[4]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[5]  
Chang Q, 1997, ANAL CHIM ACTA, V350, P97, DOI 10.1016/s0003-2670(97)00298-5
[6]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[7]   A new method for the analytical determination water in liquids and solids. [J].
Fischer, K .
ANGEWANDTE CHEMIE, 1935, 48 :0394-0396
[8]  
GLENN SJ, 1999, PITTCON 99 PITTSB C, P659
[9]  
GRIFFITHS J, 1995, MODERN COLORANTS SYN, pCH2
[10]   Electronic structure and molecular conformation in the excited charge transfer singlet-states of 9-acridyl and other aryl derivatives of aromatic amines [J].
Herbich, J ;
Kapturkiewicz, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (05) :1014-1029