Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: Evaluation of CT scoring methods, interobserver variations, and reproducibility

被引:113
作者
Broderick, LS
Shemesh, J
Wilensky, RL
Eckert, GJ
Zhou, XH
Torres, WE
Balk, MA
Rogers, WJ
Conces, DJ
Kopecky, KK
机构
[1] CHAIM SHEBA MED CTR,CARDIAC REHABIL INST,TEL AVIV,ISRAEL
[2] TEL AVIV UNIV,SACKLER SCH MED,IL-69978 TEL AVIV,ISRAEL
[3] INDIANA UNIV,SCH MED,DEPT MED,DIV CARDIOL,INDIANAPOLIS,IN 46202
[4] INDIANA UNIV,SCH MED,DEPT MED,DIV BIOSTAT,INDIANAPOLIS,IN 46202
[5] EMORY UNIV,SCH MED,DEPT RADIOL,ATLANTA,GA 30322
[6] EMORY UNIV,SCH MED,DEPT MED,DIV CARDIOL,ATLANTA,GA 30322
关键词
D O I
10.2214/ajr.167.2.8686622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was performed to evaluate new scoring methods for quantitating coronary artery calcifications with helical CT and to compare the results with those of quantitative coronary angiography in patients with suspected coronary artery disease. SUBJECTS AND METHODS. Unenhanced dual-slice helical CT and coronary angiography were performed within 24 hr of each other in 101 patients with symptoms of coronary artery disease, Coronary artery calcifications with a density above 90 H were identified on each slice and, with the same regions of interest, quantitative scoring was performed at thresholds of 90 H (new) and 130 H (old). Two mathematical algorithms (one new and one old) were evaluated for both thresholds (yielding four scoring systems), By CT imaging, we defined disease as a score of greater than zero, By angiography, we defined disease as a 50% or greater reduction in the luminal diameter of any major vessel. Interobserver variations in calcification scoring were evaluated. Seventeen of our patients also underwent a second, consecutive CT scan to determine reproducibility. RESULTS. With the new threshold and the new algorithm, the sensitivity, specificity, and accuracy of helical CT in predicting disease were 88%, 52%, and 76%, respectively. We found a moderate positive association between the total CT calcification score and the number of stenotic coronary arteries at angiography (Pearson's correlation coefficient,.43; p = .05 [analysis of variance]), The accuracy and the area under the receiver operating characteristic curve were higher with the new threshold and the new algorithm. Interobserver agreement in calcification scoring was high (intraclass correlation coefficient, .99 [n = 85]), as was reproducibility (intraclass correlation coefficient, .94 [n = 17]). Reproducibility was higher when scoring was based on the new threshold and the new algorithm. CONCLUSION. The quantity of coronary artery calcifications as measured by helical CT correlated positively with obstructive coronary artery disease as measured by angiography, Interobserver agreement and reproducibility were excellent. A new scoring method showed promise.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 15 条
  • [1] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [2] AGRESTI A, 1990, CATEGORICAL DATA ANA, P85
  • [3] SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE
    BIELAK, LF
    KAUFMANN, RB
    MOLL, PP
    MCCOLLOUGH, CH
    SCHWARTZ, RS
    SHEEDY, PF
    [J]. RADIOLOGY, 1994, 192 (03) : 631 - 636
  • [4] CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS
    BREEN, JF
    SHEEDY, PF
    SCHWARTZ, RS
    STANSON, AW
    KAUFMANN, RB
    MOLL, PP
    RUMBERGER, JA
    [J]. RADIOLOGY, 1992, 185 (02) : 435 - 439
  • [5] INFLUENCE OF AGE AND GENDER ON THE PRESENCE OF CORONARY CALCIUM DETECTED BY ULTRAFAST COMPUTED-TOMOGRAPHY
    DEVRIES, S
    WOLFKIEL, C
    FUSMAN, B
    BAKDASH, H
    AHMED, A
    LEVY, P
    CHOMKA, E
    KONDOS, G
    ZAJAC, E
    RICH, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (01) : 76 - 82
  • [6] REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY
    DEVRIES, S
    WOLFKIEL, C
    SHAH, V
    CHOMKA, E
    RICH, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) : 973 - 975
  • [7] DIFFERENCES IN PREVALENCE AND EXTENT OF CORONARY-ARTERY CALCIUM DETECTED BY ULTRAFAST COMPUTED-TOMOGRAPHY IN ASYMPTOMATIC MEN AND WOMEN
    JANOWITZ, WR
    AGATSTON, AS
    KAPLAN, G
    VIAMONTE, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (03) : 247 - 254
  • [8] COMPARISON OF SERIAL QUANTITATIVE-EVALUATION OF CALCIFIED CORONARY-ARTERY PLAQUE BY ULTRAFAST COMPUTED-TOMOGRAPHY IN PERSONS WITH AND WITHOUT OBSTRUCTIVE CORONARY-ARTERY DISEASE
    JANOWITZ, WR
    AGATSTON, AS
    VIAMONTE, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (01) : 1 - 6
  • [9] QUANTIFICATION OF CORONARY-ARTERY CALCIFICATION USING ULTRAFAST COMPUTED-TOMOGRAPHY - REPRODUCIBILITY OF MEASUREMENTS
    KAJINAMI, K
    SEKI, H
    TAKEKOSHI, N
    MABUCHI, H
    [J]. CORONARY ARTERY DISEASE, 1993, 4 (12) : 1103 - 1108
  • [10] DETECTION OF HEART CALCIFICATION WITH ELECTRON-BEAM CT - INTEROBSERVER AND INTRAOBSERVER RELIABILITY FOR SCORING QUANTIFICATION
    KAUFMANN, RB
    SHEEDY, PF
    BREEN, JF
    KELZENBERG, JR
    KRUGER, BL
    SCHWARTZ, RS
    MOLL, PP
    [J]. RADIOLOGY, 1994, 190 (02) : 347 - 352