Diffuse optical tomography of highly heterogeneous media

被引:49
作者
Ntziachristos, V [1 ]
Hielscher, AH
Yodh, AG
Chance, B
机构
[1] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Biochem Biophys, Philadelphia, PA 19104 USA
[3] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Ctr Mol Imaging Res, Charlestown, MA 02129 USA
[4] SUNY Hlth Sci Ctr, Dept Pathol, Brooklyn, NY 11201 USA
[5] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[6] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
关键词
artifacts; correction; diffuse media; diffuse optical tomography; reconstruction;
D O I
10.1109/42.929613
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We investigate the performance of diffuse optical tomography to image highly heterogeneous media, such as breast tissue, as a function of background heterogeneity, To model the background heterogeneity, we have employed the functional information derived from Gadolinium-enhanced magnetic resonance images of the breast. We demonstrate that overall image quality and quantification accuracy worsens as the background heterogeneity increases. Furthermore we confirm the appearance of characteristic artifacts at the boundaries that scale with background heterogeneity. These artifacts are very similar to the ones seen in clinical examinations and can be misinterpreted as actual objects if not accounted for. To eliminate the artifacts and improve the overall image reconstruction, we apply a data-correction algorithm that yields superior reconstruction results and is virtually independent of the degree of the background heterogeneity.
引用
收藏
页码:470 / 478
页数:9
相关论文
共 18 条
[1]   CONTRIBUTION OF THE MITOCHONDRIAL COMPARTMENT TO THE OPTICAL-PROPERTIES OF THE RAT-LIVER - A THEORETICAL AND PRACTICAL APPROACH [J].
BEAUVOIT, B ;
KITAI, T ;
CHANCE, B .
BIOPHYSICAL JOURNAL, 1994, 67 (06) :2501-2510
[2]   CONTRAST-ENHANCED NMR IMAGING - ANIMAL STUDIES USING GADOLINIUM-DTPA COMPLEX [J].
BRASCH, RC ;
WEINMANN, HJ ;
WESBEY, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) :625-630
[3]  
CHANCE PB, 1989, J APPL OPT, V28, P2331
[4]   Optical imaging of anatomical maps derived from magnetic resonance images using time-independent optical sources [J].
Chang, JW ;
Graber, HL ;
Koo, PC ;
Aronson, R ;
Barbour, SLS ;
Barbour, RL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (01) :68-77
[5]  
Hielscher A.H., 1998, OSA TRENDS OPTICS PH, V21, P156
[6]  
KAK AC, 1988, PRINCIPLES COMPUTERI, P208
[7]   Comparison between intrinsic and extrinsic contrast for malignancy detection using NIR mammography [J].
Ntziachristos, V ;
Yodh, AG ;
Schnall, M ;
Chance, B .
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 :565-570
[8]   Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement [J].
Ntziachristos, V ;
Yodh, AG ;
Schnall, M ;
Chance, B .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (06) :2767-2772
[9]   Time-correlated single photon counting imager for simultaneous magnetic resonance and near-infrared mammography [J].
Ntziachristos, V ;
Ma, XH ;
Chance, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12) :4221-4233
[10]   Differential diffuse optical tomography [J].
Ntziachristos, V ;
Chance, B ;
Yodh, AG .
OPTICS EXPRESS, 1999, 5 (10) :230-242