Acute Adverse Reactions to Gadolinium-Based Contrast Agents in CMR Multicenter Experience With 17,767 Patients From the EuroCMR Registry

被引:61
作者
Bruder, Oliver [1 ]
Schneider, Steffen [2 ]
Nothnagel, Detlev [3 ]
Pilz, Guenter [4 ]
Lombardi, Massimo [5 ]
Sinha, Anil [6 ]
Wagner, Anja [7 ]
Dill, Thorsten [8 ]
Frank, Herbert [9 ]
van Rossum, Albert [10 ]
Schwitter, Juerg [11 ]
Nagel, Eike [12 ]
Senges, Jochen
Sabin, Georg [1 ]
Sechtem, Udo [13 ]
Mahrholdt, Heiko [13 ]
机构
[1] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[2] Inst Herzinfarktforsch, Dept Biometr, Ludwigshafen, Germany
[3] Klinikum Ludwigsburg, Dept Cardiol, Ludwigshafen, Germany
[4] Hosp Agatharied, Dept Cardiol, Hausham, Germany
[5] Fdn Consiglio Nazl Ric Reg Toscana G Monasterio, Pisa, Italy
[6] Klinikum Coburg, Dept Cardiol, Coburg, Germany
[7] Drexel Univ, Coll Med, Hahnemann Univ Hosp, Philadelphia, PA 19104 USA
[8] Krankenhaus Benrath, Dept Internal Med, Dusseldorf, Germany
[9] Donauklinikum Tulln, Dept Internal Med & Cardiol, Tulln, Austria
[10] Vrije Univ, Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[11] CHUV Univ Lausanne, CHU Vaudois, Lausanne, Switzerland
[12] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
[13] Robert Bosch Med Ctr, Dept Cardiol, Stuttgart, Germany
关键词
cardiac magnetic resonance; gadolinium; off-label" use; safety; CARDIOVASCULAR-MAGNETIC-RESONANCE; MEDIA; FREQUENCY; SEVERITY;
D O I
10.1016/j.jcmg.2011.06.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to assess the frequency, manifestation, and severity of acute adverse reactions associated with administration of several gadolinium-based contrast agents to patients who underwent cardiac magnetic resonance (CMR) imaging in the EuroCMR (European Cardiovascular Magnetic Resonance) Registry multinational and multicenter setting. BACKGROUND The frequency, manifestations, and severity of acute adverse reactions associated with gadolinium-based contrast agents in the specific setting of cardiovascular magnetic resonance have not been systematically evaluated yet. METHODS This is a multicenter and multinational registry with consecutive enrollment of patients in 45 European centers. During the current observation, 17,767 doses of gadolinium-based contrast agent were administered to 17,767 patients. The mean dose was 25.6 ml (range 5 to 80 ml), which is equivalent to 0.128 mmol/kg (range 0.012 to 0.3 mmol/kg). RESULTS Thirty acute adverse reactions due to contrast administration occurred (0.17%). All reactions were classified as mild according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (9 of 30), followed by nausea (7 of 30), and anxiety (6 of 30). The event rate ranged from 0.06% (linear nonionic agent gadodiamide) to 0.47% (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR imaging, ranging from 0.1% (risk stratification in suspected coronary artery disease) to 0.42% (viability in known coronary artery disease). CONCLUSIONS The incidence of acute adverse reactions after administration of gadolinium-based contrast in the "off-label" setting of CMR in our population was not different from the incidence in the U.S. Food and Drug Administration-approved general radiology setting. Thus, the off-label use of gadolinium-based contrast in CMR should be regarded as safe concerning the frequency, manifestation, and severity of acute events. (J Am Coll Cardiol Img 2011;4:1171-6) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:1171 / 1176
页数:6
相关论文
共 14 条
[1]   Acute Adverse Reactions to Gadopentetate Dimeglumine and Gadobenate Dimeglumine: Experience With 32,659 Injections [J].
Abujudeh, Hani H. ;
Kosaraju, Vijaya K. ;
Kaewlai, Rathachai .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) :430-434
[2]  
[Anonymous], MAN CONTR MED VERS 6
[3]   Assessment of Adverse Reaction Rates to a Newly Approved MRI Contrast Agent: Review of 23,553 Administrations of Gadobenate Dimeglumine [J].
Bleicher, Andrew G. ;
Kanal, Emanuel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) :W307-W311
[4]   EuroCMR (European Cardiovascular Magnetic Resonance) Registry Results of the German Pilot Phase [J].
Bruder, Oliver ;
Schneider, Steffen ;
Nothnagel, Detlef ;
Dill, Thorsten ;
Hombach, Vinzenz ;
Schulz-Menger, Jeanette ;
Nagel, Eike ;
Lombardi, Massimo ;
van Rossum, Albert C. ;
Wagner, Anja ;
Schwitter, Juerg ;
Senges, Jochen ;
Sabin, Georg V. ;
Sechtem, Udo ;
Mahrholdt, Heiko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (15) :1457-1466
[5]   Frequency and severity of acute allergic-like reactions to gadolinium-containing IV contrast media in children and adults [J].
Dillman, Jonathan R. ;
Ellis, James H. ;
Cohan, Richard H. ;
Strouse, Peter J. ;
Jan, Sophia C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :1533-1538
[6]   Frontiers in cardiovascular magnetic resonance [J].
Fuster, V ;
Kim, RJ .
CIRCULATION, 2005, 112 (01) :135-144
[7]   ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology [J].
Hendel, Robert C. ;
Patel, Manesh R. ;
Kramer, Christopher M. ;
Poon, Michael ;
Hendel, Robert C. ;
Brindis, Ralph G. ;
Hendel, Robert C. ;
Douglas, Pamela S. ;
Peterson, Eric D. ;
Wolk, Michael J. ;
Allen, Joseph M. ;
Patel, Manesh R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) :1475-1497
[8]   Frequency and Severity of Adverse Effects of Iodinated and Gadolinium Contrast Materials: Retrospective Review of 456,930 Doses [J].
Hunt, Christopher H. ;
Hartman, Robert P. ;
Hesley, Gina K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1124-1127
[9]   Acute adverse reactions to magnetic resonance contrast media gadolinium chelates [J].
Li, A. ;
Wong, C. S. ;
Wong, M. K. ;
Lee, C. M. ;
Yeung, M. C. Au .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (941) :368-371
[10]   Adverse reactions to gadolinium contrast media: A review of 36 cases [J].
Murphy, KJ ;
Brunberg, JA ;
Cohan, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :847-849