Wear and Range of Motion of Different Femoral Head Sizes

被引:55
作者
Hammerberg, Eric Mark [1 ]
Wan, Zhinian [1 ]
Dastane, Manish [1 ]
Dorr, Lawrence D. [1 ]
机构
[1] Hosp Good Samaritan, Arthrit Inst, Los Angeles, CA 90017 USA
关键词
wear; Durasul; range of motion; total hip; head size; TOTAL HIP-ARTHROPLASTY; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; RADIOGRAPHIC EVALUATION; CLINICAL-PERFORMANCE; ACETABULAR CUP; REPLACEMENT; DISLOCATION; COMPONENTS; LINERS;
D O I
10.1016/j.arth.2009.07.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Femoral head sizes greater than 32 mm are more prevalent with current total hip arthroplasty. We hypothesized that linear wear rates of Durasul highly cross-linked polyethylene would not differ with different head sizes. We also compared the range of motion of the hip. Ninety-four consecutive arthroplasties in 84 patients were studied for a mean 3.6 +/- 0.7 years. There was no statistical difference in linear wear rates and annual or total penetration rates when 28-mm and 32-mm heads were compared to 38-mm and 44-mm heads. Volumetric wear was 12.4 mm(3)/y higher with bigger heads. Range of motion did not differ. Larger femoral head sizes show no evidence of an accelerated wear pattern when used with Durasul.
引用
收藏
页码:839 / 843
页数:5
相关论文
共 41 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
AMSTUTZ HC, 1975, CLIN ORTHOP RELAT R, P124
[3]
[Anonymous], 1979, Clin Orthop Relat Res
[4]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[5]
Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners [J].
Bradford, L ;
Baker, DA ;
Graham, J ;
Chawan, A ;
Ries, MD ;
Pruitt, LA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06) :1271-1282
[6]
Third-body wear of highly cross-linked polyethylene in a hip simulator [J].
Bragdon, CR ;
Jasty, M ;
Muratoglu, OK ;
O'Connor, DO ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :553-561
[7]
Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[8]
Femoral head sizes larger than 32 mm against highly cross-linked polyethylene [J].
Burroughs, BR ;
Rubash, HE ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :150-157
[9]
RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[10]
Biomechanics of large femoral heads - What they do and don't do [J].
Crowninshield, RD ;
Maloney, WJ ;
Wentz, DH ;
Humphrey, SM ;
Blanchard, CR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :102-107