Potentiometric immunoassay with quantum dot labels

被引:71
作者
Thuerer, Reto
Vigassy, Tamas
Hirayama, Martina
Wang, Joseph
Bakker, Eric
Pretsch, Ernoe
机构
[1] Zurcher Hochschule Winterthur, Dept Tech Informat & Nat Wissensch, CH-8400 Winterthur, Switzerland
[2] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
[3] Arizona State Univ, Biodesign Inst, Tempe, AZ 85287 USA
[4] Arizona State Univ, Fulton Sch Engn, Tempe, AZ 85287 USA
[5] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac070932m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric sensors based on polymer membrane electrodes, if properly optimized, are useful for measurements at trace levels. The expected independence of the electrochemical signal of the sample size makes them extremely attractive for measurements in small volumes. Here, we report on electrodes for the potentiometric detection of cadmium ions that reach a detection limit of 6 nM and utilize a Na+-selective electrode as pseudoreference in order to facilitate measurements in 150-mu L samples. A potentiometric immunoassay of mouse IgG is performed via CdSe quantum dot labels on a secondary antibody according to a sandwich immunoassay protocol in a microtiter plate format. The CdSe quantum dots are found to be easily dissolved/oxidized in a matter of minutes with hydrogen peroxide, allowing us to maintain the pH at a near-neutral value. The potentiometric protein immunoassay exhibits a log-linear response ranging from 0.15 to 4.0 pmol of IgG, with a detection limit of < 10 fmol in 150-mu L sample wells.
引用
收藏
页码:5107 / 5110
页数:4
相关论文
共 26 条
[1]  
Ammann, 1986, ION SELECTIVE MICROE
[2]   Gold nanoparticle-based quantitative electrochemical detection of amplified human cytomegalovirus DNA using disposable microband electrodes [J].
Authier, L ;
Grossiord, C ;
Brossier, P ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4450-4456
[3]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[4]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[5]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[6]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[7]   USE OF SOLID-PHASE BIOCHEMISTRY FOR POTENTIOMETRIC ENZYME-IMMUNOASSAY OF OESTRADIOL-17-BETA - PRELIMINARY-REPORT [J].
BOITIEUX, JL ;
LEMAY, C ;
DESMET, G ;
THOMAS, D .
CLINICA CHIMICA ACTA, 1981, 113 (02) :175-182
[8]   An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label [J].
Chu, X ;
Fu, X ;
Chen, K ;
Shen, GL ;
Yu, RQ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1805-1812
[9]   Potentiometric biosensing of proteins with ultrasensitive ion-selective microelectrodes and nanoparticle labels [J].
Chumbimuni-Torres, Karin Y. ;
Dai, Zong ;
Rubinova, Nastassia ;
Xiang, Yun ;
Pretsch, Erno ;
Wang, Joseph ;
Bakker, Eric .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (42) :13676-13677
[10]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528