共 56 条
First-Pass and High-Resolution Steady-State Magnetic Resonance Angiography of the Peripheral Arteries With Gadobenate Dimeglumine An Assessment of Feasibility and Diagnostic Performance
被引:14
作者:
Anzidei, Michele
[1
]
Napoli, Alessandro
[1
]
Zaccagna, Fulvio
[1
]
Marincola, Beatrice Cavallo
[1
]
Zini, Chiara
[2
]
Kirchin, Miles A.
[1
]
Catalano, Carlo
[1
]
Passariello, Roberto
[1
]
机构:
[1] Univ Roma La Sapienza, Dept Radiol Sci, I-00161 Rome, Italy
[2] Bracco Imaging SpA, Worldwide Med & Regulatory Affairs, Milan, Italy
关键词:
magnetic resonance angiography;
peripheral arterial;
occlusive disease;
gadolinium contrast agents;
gadobenate dimeglumine;
vascular imaging;
ENHANCED MR-ANGIOGRAPHY;
DIGITAL-SUBTRACTION-ANGIOGRAPHY;
NEPHROGENIC SYSTEMIC FIBROSIS;
AORTOILIAC OCCLUSIVE DISEASE;
STAGE-RENAL-DISEASE;
HUMAN SERUM-ALBUMIN;
CONTRAST AGENT;
GADOPENTETATE DIMEGLUMINE;
GADOFOSVESET TRISODIUM;
RELAXATION RATES;
D O I:
10.1097/RLI.0b013e3182021879
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
100231 [临床病理学];
100902 [航空航天医学];
摘要:
Purpose: To assess the feasibility of combined first-pass (FP) and steady-state (SS) contrast-enhanced magnetic resonance angiography (MRA) of the peripheral arteries with gadobenate dimeglumine (MultiHance) and to evaluate diagnostic performance relative to digital subtraction angiography (DSA). Materials and Methods: A total of 35 patients with symptomatic peripheral arterial occlusive disease (PAOD) underwent FP MRA (repetition time [TR]/echo time [TE]/flip angle [FA]/acquisition time [TA] = 3.5/1.2/30 degrees/14s) at 1.5T after intravenous injection of 10 mL of gadobenate dimeglumine. Thereafter, SS imaging of the calf (TR/TE/FA/TA = 7.5/2.3/20 degrees/40130s) and femoropopliteal (TR/TE/FA/TA = 7.5/2.3/18 degrees/130-240s) regions was performed after a second injection of 5 mL of gadobenate dimeglumine. All patients underwent conventional DSA. Three readers reviewed separate FP and FP+SS MRA datasets for image quality and presence/absence of clinically relevant PAOD. A fourth independent observer evaluated DSA images. The diagnostic performance (sensitivity, specificity, positive and negative predictive values) achieved with each dataset was determined and compared. Inter-reader agreement was assessed using kappa statistics. Results: The image quality of 134 of 140 vascular regions was optimal or adequate on SS MRA. Inter-reader agreement was good to very good for assessments of FP (kappa = 0.725) and combined FP+SS images (kappa = 0.866). SS images improved diagnostic confidence in 34 (48.6%) femoropoliteal and 46 (65.7%) crural regions and altered final diagnosis in 8 (11.4%) and 10 (14.3%) regions, respectively. Global diagnostic accuracy increased from 92.9% on FP images to 95.9% on FP+SS images, with significant (P = 0.0384) improvement in the crural region. Conclusion: SS MRA of the peripheral arteries is feasible with gadobenate dimeglumine and potentially improves diagnostic performance in patients with symptomatic PAOD.
引用
收藏
页码:307 / 316
页数:10
相关论文

