Absence of systemic toxicity in mouse model towards BaTiO3 nanoparticulate based eluate treatment

被引:46
作者
Dubey, Ashutosh Kumar [1 ]
Thrivikraman, Greeshma [1 ]
Basu, Bikramjit [1 ]
机构
[1] Indian Inst Sci, Ctr Mat Res, Lab Biomat, Bangalore 560012, Karnataka, India
关键词
POLYETHYLENE PARTICLES; BONE-RESORPTION; WEAR PARTICLES; HYDROXYAPATITE NANOPARTICLES; ELECTRICAL-STIMULATION; IN-VITRO; SIZE; HIP; DEBRIS; MACROPHAGES;
D O I
10.1007/s10856-015-5414-6
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
One of the existing issues in implant failure of orthopedic biomaterials is the toxicity induced by the fine particles released during long term use in vivo, leading to acute inflammatory response. In developing a new class of piezobiocomposite to mimic the integrated electrical and mechanical properties of bone, bone-mimicking physical properties as well as in vitro cytocompatibility properties have been achieved with spark plasma sintered hydroxyapatite (HA)-barium titanate (BaTiO3) composites. However, the presence of BaTiO3 remains a concern towards the potential toxicity effect. To address this issue, present work reports the first result to conclusively confirm the non-toxic effect of HA-BaTiO3 piezobiocomposite nanoparticulates, in vivo. Twenty BALB/c mice were intraarticularly injected at their right knee joints with different concentrations of HA-BaTiO3 composite of up to 25 mg/ml. The histopathological examination confirmed the absence of any trace of injected particles or any sign of inflammatory reaction in the vital organs, such as heart, spleen, kidney and liver at 7 days post-exposure period. Rather, the injected nanoparticulates were found to be agglomerated in the vicinity of the knee joint, surrounded by macrophages. Importantly, the absence of any systemic toxicity response in any of the vital organs in the treated mouse model, other than a mild local response at the site of delivery, was recorded. The serum biochemical analyses using proinflammatory cytokines (TNF-alpha and IL-1 beta) also complimented to the non-immunogenic response to injected particulates. Altogether, the absence of any inflammatory/ adverse reaction will open up myriad of opportunities for BaTiO3 based piezoelectric implantable devices in biomedical applications.
引用
收藏
页数:11
相关论文
共 70 条
[1]
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]
GENERATION OF ELECTRIC POTENTIALS BY BONE IN RESPONSE TO MECHANICAL STRESS [J].
BASSETT, CAL ;
BECKER, RO .
SCIENCE, 1962, 137 (3535) :1063-&
[3]
An in vitro study of electrically active hydroxyapatite-barium titanate ceramics using Saos-2 cells [J].
Baxter, Frances R. ;
Turner, Irene G. ;
Bowen, Christopher R. ;
Gittings, Jonathan P. ;
Chaudhuri, Julian B. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (08) :1697-1708
[4]
Dielectric and piezoelectric properties of hydroxyapatite-BaTiO3 composites [J].
Bowen, C. R. ;
Gittings, J. ;
Turner, I. G. ;
Baxter, F. ;
Chaudhuri, J. B. .
APPLIED PHYSICS LETTERS, 2006, 89 (13)
[5]
Catelas I, 1998, J BIOMED MATER RES, V41, P600, DOI 10.1002/(SICI)1097-4636(19980915)41:4<600::AID-JBM12>3.3.CO
[6]
2-7
[7]
A new approach for toughening of ceramics [J].
Chen, XM ;
Yang, B .
MATERIALS LETTERS, 1997, 33 (3-4) :237-240
[8]
Effect of Particle Size of Hydroxyapatite Nanoparticles on its Biocompatibility [J].
Ding, Tingting ;
Xue, Yang ;
Lu, Hua ;
Huang, Zhewei ;
Sun, Jiao .
IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2012, 11 (04) :336-340
[9]
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO
[10]
2-M