Analytical performance characteristics of thin and thick film amperometric microcells

被引:16
作者
Gyurcsányi, RE
Cristalli, A
Nagy, G
Nagy, L
Corder, C
Pendley, BD
Ufer, S
Nagle, HT
Neuman, MR
Lindner, E [1 ]
机构
[1] Univ Memphis, Joint Grad Program Biomed Engn, Memphis, TN 38152 USA
[2] Tech Univ Budapest, Hungarian Acad Sci, Tech Analyt Chem Res Grp, H-1111 Budapest, Hungary
[3] Janus Pannonius Univ, Hungarian Acad Sci, Dept Gen & Phys Chem, Res Grp Chem Sensors, Pecs, Hungary
[4] Rhodes Coll, Dept Chem, Memphis, TN 38112 USA
[5] N Carolina State Univ, Dept Elect & Comp Engn, Raleigh, NC 27695 USA
[6] Univ Tennessee, Ctr Hlth Sci, Herff Coll Engn, Memphis, TN 38152 USA
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 369卷 / 3-4期
关键词
D O I
10.1007/s002160000614
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 33 条
  • [1] Adams R.N., 1969, Electrochemistry at Solid Electrodes
  • [2] MASS-PRODUCTION OF BIOSENSORS
    ALVAREZICAZA, M
    BILITEWSKI, U
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (11) : A525 - A533
  • [3] BLUM W, 1949, PRINCIPLES ELECTROPL, P382
  • [4] A COMPARISON OF THE CHRONOAMPEROMETRIC RESPONSE AT INLAID AND RECESSED DISK MICROELECTRODES
    BOND, AM
    LUSCOMBE, D
    OLDHAM, KB
    ZOSKI, CG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2): : 1 - 14
  • [5] Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors
    Carelli, I
    Chiarotto, I
    Curulli, A
    Palleschi, G
    [J]. ELECTROCHIMICA ACTA, 1996, 41 (11-12) : 1793 - 1800
  • [6] Dempsey E, 1997, ANAL CHIM ACTA, V346, P341
  • [7] Finite element simulation of the chronoamperometric response of recessed and protruding microdisc electrodes
    Ferrigno, R
    Brevet, PF
    Girault, HH
    [J]. ELECTROCHIMICA ACTA, 1997, 42 (12) : 1895 - 1903
  • [8] GAHL WA, 1982, OBSTET GYNECOL, V60, P297
  • [9] Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels
    Gavin, PF
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (18) : 3838 - 3845
  • [10] Studies towards a disposable screen-printed amperometric biosensor for progesterone
    Hart, JP
    Pemberton, RM
    Luxton, R
    Wedge, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) : 1113 - 1121