An inter-platform repeatability study investigating real-time amplification of plasmid DNA

被引:15
作者
Donald, CE
Qureshi, F
Burns, MJ
Holden, MJ
Blasic, JR
Woolford, AJ
机构
[1] Biomol Innovat Team LGC Ltd, Teddington TW11 0LY, Middx, England
[2] NIST, Bioproc Measurement Grp, Gaithersburg, MD 20899 USA
关键词
D O I
10.1186/1472-6750-5-15
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: The wide variety of real-time amplification platforms currently available has determined that standardisation of DNA measurements is a fundamental aspect involved in the comparability of results. Statistical analysis of the data arising from three different real-time platforms was conducted in order to assess inter-platform repeatability. On three consecutive days two PCR reaction mixes were used on each of the three amplification platforms - the LightCycler(R), ABI PRISM(R) 7700 and Rotor Gene 3000(TM). Real-time PCR amplification using a fluorogenic 5' exonuclease assay was performed in triplicate on negative controls and DNA plasmid dilutions of 108 - 102 copies to give a total of 24 reactions per PCR experiment. Results: The results of the statistical analyses indicated that the platform with the most precise repeatability was the ABI PRISM(R) 7700 when coupled with the FastStart PCR reaction mix. It was also found that there was no obvious relationship between plasmid copy number and repeatability. An ANOVA approach identified the factors that significantly affected the results, in descending order of magnitude, as: plasmid copy number, platform, PCR reaction mix and day ( on which the experiment was performed). Conclusion: In order to deliver useful, informative genetic tests, standardisation of real-time PCR detection platforms to provide repeatable, reliable results is warranted. In addition, a better understanding of inter-assay and intra-assay repeatability is required.
引用
收藏
页数:10
相关论文
共 27 条
[1]   Amplification efficiency of thermostable DNA polymerases [J].
Arezi, B ;
Xing, WM ;
Sorge, JA ;
Hogrefe, HH .
ANALYTICAL BIOCHEMISTRY, 2003, 321 (02) :226-235
[2]   Kinetic Outlier Detection (KOD) in real-time PCR -: art. no. e105 [J].
Bar, T ;
Ståhlberg, A ;
Muszta, A ;
Kubista, M .
NUCLEIC ACIDS RESEARCH, 2003, 31 (17) :e105
[3]  
Bell AS, 2002, TRENDS PARASITOL, V18, P337, DOI 10.1016/S1471-4922(02)02331-0
[4]  
Foy CA, 2001, CLIN CHEM, V47, P990
[5]   Molecular diagnosis of Epstein-Barr virus [J].
Häusler, M ;
Scheirauer, S ;
Ritter, K ;
Kleines, M .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2003, 3 (01) :81-92
[6]   Random variation and concentration effects in PCR [J].
Jagers, P ;
Klebaner, F .
JOURNAL OF THEORETICAL BIOLOGY, 2003, 224 (03) :299-304
[7]   The PCR plateau phase - towards an understanding of its limitations [J].
Kainz, P .
BIOCHIMICA ET BIOPHYSICA ACTA-GENE STRUCTURE AND EXPRESSION, 2000, 1494 (1-2) :23-27
[8]   Quantitative real-time RT-PCR using hybridization probes and imported standard curves for cytokine gene expression analysis [J].
Kühne, BS ;
Oschmann, P .
BIOTECHNIQUES, 2002, 33 (05) :1078-+
[9]   Validation of a quantitative method for real time PCR kinetics [J].
Liu, WH ;
Saint, DA .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2002, 294 (02) :347-353
[10]  
Lyons SR, 2000, J CLIN MICROBIOL, V38, P2362